CAGE NUTS

Cage nuts for electrical continuity

A design with dedicated contact features. Verify electrical continuity on the actual substrate, coating and assembly.

Documented threads
M4 · M5 · M6 · M8 · M10 · M12
Configurations
6
Cage nuts for electrical continuity

Technical drawing

Cage nuts for electrical continuity

Type identification drawing, not a manufacturing drawing. Use the hole and permitted thickness of the selected variant.

Variants and dimensional data

ThreadPitch · mmHole · mmSheet thickness · mmA · mmC · mmD · mmE · mmF · mmG · mm
M40.79.5 × 9.51–2139.58.20.4513.56
M50.89.5 × 9.51–2139.58.20.4513.56
M619.5 × 9.51–2139.58.20.4513.56
M81.2514 × 142–3.820.416.512.50.620.410.5
M101.514 × 142–3.820.416.512.50.620.410.5
M121.7514 × 142–3.820.416.512.50.620.410.5

Materials, classes and finishes

Nut materialNut classCage materialFinish
To quotation specification—To quotation specificationTo quotation specification

Combinations depend on size, hole and sheet thickness: select a variant in the configurator to check them. No stock availability is inferred.

Configure the variant

Request this configuration

Documentation and mounting

Download technical data sheet PDF

Mounting and application

Check hole preparation, thickness, accessibility and proper engagement before tightening. Compatibility data does not replace joint verification. Supply and documentation are agreed in the quotation.

Request a standard or custom configuration

Continue to the form to send your enquiry and attach a drawing.

Dueemme Sidol
Panoramica privacy

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.