ASTM FASTENERS · TECHNICAL GUIDE

ASTM F3111 — Heavy Hex structural assemblies

Very-high-strength bolt, nut and washer assemblies, handled through a specification distinct from F3125.

Reference
ASTM F3111 — 23
Configuration
To specification and drawing
Dimensions
Specify units and tolerances
Supply
Confirm feasibility and documents

Technical drawing and dimensions to specify

Diagram of dimensions to specify

Family selection guide. The drawing only identifies dimensions to specify; it does not identify a certified item, an available size range or a complete assembly. Final geometry and dimensions must match the approved drawing. For special assemblies request the complete system drawing; the hex-bolt schematic does not depict the installation mechanism.

Dimensional data for the request

SymbolRequired informationUnits
dNominal thread and pitchmm or inches, specify
LUnder-head length of the illustrated hex boltmm or inches, specify
bThreaded lengthmm or inches, specify

Attach the dimensional standard or drawing, tolerances, quantity and configuration. Mechanical properties and grades appear below; they are not geometric dimensions.

Materials, grades and technical requirements

A complete assembly, not a generic bolt

Identify the entire system: bolt, nut, washers, dimensions, finish, equipment and installation procedure. Components with the same diameter are not automatically interchangeable.

Data required for supply

Technical fieldRequirement
Rm min.200 ksi
ConfigurationHeavy Hex
DimensionsDiameter, length and grip range of the selected system
InstallationInstructions and checks for the specific assembly

Do not infer equivalence between standards from tensile strength in ksi alone. Check the standard and proposed system for temperature, exposure and outdoor-use limitations.

Specify the complete system

F3111 covers Heavy Hex assemblies with a minimum tensile strength of 200 ksi. Selection requires review of dimensions, installation, tests and documentation.

Send project requirements and conditions

Dueemme assesses sourcing against the project specification, without treating generic components as substitutes for the assembly. Include installation provisions and inspection requirements.

Service environment

F3111 restricts the permitted service environments. It must not be extended automatically to uncovered exterior structures or highly corrosive environments. Provide project conditions for application review.

The intended scope includes normally dry sheltered environments; exterior locations under a roof require the specified structural-system protection. Unroofed exterior exposure, aggressive chemical environments, almost continuous condensation, immersion in water or soil, and cathodically protected systems are excluded.

Technical documentation

Dueemme technical sheet

Download technical PDF ↓

Assembly and traceability

Lot, markings, component list and conformity documents relevant to the supply.

EN 10204 3.1 · DoP · CoC

State the required documents. Applicability and availability are confirmed during enquiry review.

Testing and coatings

Dimensional reports, mechanical tests, coating reports and ROCAP where applicable to the specification.

Application sectors

Steelwork, structures and infrastructure.

Dueemme industries →
RFQ / B2B

Have a structural or ASTM specification?

Build your enquiry. In the next step, add your contact details and attach the specification, bill of materials or drawing.

Required documentation
Dueemme Sidol
Panoramica privacy

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.