EPDM-lined pipe clamps
The EPDM liner introduces an elastomeric layer between pipe and clamp. It limits rigid contact and vibration transfer through the connection; acoustic performance depends on the complete installation.

Characteristics and selection criteria
Check clamping range, threaded connection and liner compression. The clamp must support the pipe without crushing the liner into a rigid bridge.
Selection information
- Actual outside diameter, pipe material and wall thickness.
- Full-pipe weight, insulation and any dynamic actions.
- Liner, connection and compatibility of screws, rods and substrate.
- Temperature, environment, thermal movement and acoustic requirements.
Installation and connection checks
Identify the configuration, check the complete load path to the substrate and apply the design-specific installation sequence. Avoid excessive liner compression and separately verify sliding-support or fixed-point operation.
Tables checked on 18 November 2026. Values refer to the listed configuration: “—” means unavailable, not zero. DN, nominal inch size and outside diameter in mm are distinct quantities. Availability and component combinations are confirmed through the technical enquiry.
Series and technical tables
Two-side-screw clamp with combined connectionDM-CI01 · 22 configurationsDescription and technical table ↓

Characteristics
The EPDM liner introduces an elastomeric layer between pipe and clamp. It limits rigid contact and vibration transfer through the connection; acoustic performance depends on the complete installation.
Body material: Steel. Liner: EPDM.
Check clamping range, threaded connection and liner compression. The clamp must support the pipe without crushing the liner into a rigid bridge.
Use the configuration reference and size in your technical enquiry.
Configuration technical table
Dimensions are in mm where stated; G identifies the listed connection. B, H and other letters retain their configuration-specific definitions: request technical review for the dimensioned drawing. Plug dimensions are not pipe diameter.
| Reference | D [mm] | D [“] | G | B [mm] | H [mm] | b x s [mm] | DN |
|---|---|---|---|---|---|---|---|
| DM-CI01-01 | 12-15 | 1/4 | M8/M10 | 61 | 43 | 20 x 1,50 | — |
| DM-CI01-02 | 15-18 | 3/8 | M8/M10 | 65 | 49 | 20 x 1,50 | 10 |
| DM-CI01-03 | 20-24 | 1/2 | M8/M10 | 68 | 52 | 20 x 1,50 | 15 |
| DM-CI01-04 | 23-28 | 3/4 | M8/M10 | 75 | 58 | 20 x 1,50 | 20 |
| DM-CI01-05 | 32-36 | 1” | M8/M10 | 82 | 63 | 20 x 1,50 | 25 |
| DM-CI01-06 | 38-44 | 1 1/4 | M8/M10 | 87 | 74 | 20 x 1,50 | 32 |
| DM-CI01-07 | 44-50 | 1 1/2 | M8/M10 | 95 | 77 | 20 x 1,50 | 40 |
| DM-CI01-08 | 54-58 | — | M8/M10 | 101 | 85 | 20 x 1,50 | — |
| DM-CI01-09 | 59-65 | 2” | M8/M10 | 110 | 91 | 20 x 1,50 | 50 |
| DM-CI01-10 | 68-72 | — | M10 | 130 | 88 | 25 x 3,00 | — |
| DM-CI01-11 | 74-80 | 2 1/2 | M8/M10 | 131 | 108 | 25 x 2,50 | 65 |
| DM-CI01-12 | 83-93 | 3” | M8/M10 | 140 | 120 | 25 x 2,50 | 80 |
| DM-CI01-13 | 99-105 | — | M8/M10 | 155 | 133 | 25 x 2,50 | — |
| DM-CI01-14 | 108-118 | 4” | M8/M10 | 161 | 140 | 25 x 2,50 | 100 |
| DM-CI01-15 | 121-127 | — | M8/M10 | 183 | 159 | 25 x 2,50 | — |
| DM-CI01-16 | 132-143 | 5” | M8/M10 | 194 | 170 | 25 x 2,50 | 125 |
| DM-CI01-17 | 150-154 | — | M10 | 200 | 170 | 30 x 2,50 | — |
| DM-CI01-18 | 159-169 | 6” | M8/M10 | 232 | 202 | 25 x 3,00 | 150 |
| DM-CI01-19 | 198-202 | — | M8/M10 | 268 | 238 | 25 x 3,00 | — |
| DM-CI01-20 | 210-212 | — | M8/M10 | 273 | 241 | 25 x 3,00 | — |
| DM-CI01-21 | 216-225 | 8" | M8/M10 | 283 | 251 | 25 x 3,00 | 200 |
| DM-CI01-22 | 249-254 | — | M8/M10 | 320 | 270 | 25 x 2,50 | — |
Tables checked on 18 November 2026. Values refer to the listed configuration: “—” means unavailable, not zero. DN, nominal inch size and outside diameter in mm are distinct quantities. Availability and component combinations are confirmed through the technical enquiry.
Lined clamp with M8 connectionDM-CI02 · 8 configurationsDescription and technical table ↓

Characteristics
The EPDM liner introduces an elastomeric layer between pipe and clamp. It limits rigid contact and vibration transfer through the connection; acoustic performance depends on the complete installation.
Body material: Steel. Liner: EPDM.
Check clamping range, threaded connection and liner compression. The clamp must support the pipe without crushing the liner into a rigid bridge.
Use the configuration reference and size in your technical enquiry.
Configuration technical table
Dimensions are in mm where stated; G identifies the listed connection. B, H and other letters retain their configuration-specific definitions: request technical review for the dimensioned drawing. Plug dimensions are not pipe diameter.
| Reference | D [mm] | D ["] | G | B [mm] | H [mm] | b x s [mm] |
|---|---|---|---|---|---|---|
| DM-CI02-01 | 11-14 | 1/4 | M8 | 55 | 34 | 20×1,5 |
| DM-CI02-02 | 15-18 | 3/8 | M8 | 60 | 35 | 20×1,5 |
| DM-CI02-03 | 20-23 | 1/2 | M8 | 65 | 36 | 20×1,5 |
| DM-CI02-04 | 25-28 | 3/4 | M8 | 70 | 43 | 20×1,5 |
| DM-CI02-05 | 32-35 | 1 | M8 | 77 | 52 | 20×1,5 |
| DM-CI02-06 | 40-43 | 1 1/4 | M8 | 85 | 56 | 20×1,5 |
| DM-CI02-07 | 48-51 | 1 1/2 | M8 | 92 | 63 | 20×1,5 |
| DM-CI02-08 | 57-63 | 2 | M8 | 102 | 73 | 20×1,5 |
Tables checked on 18 November 2026. Values refer to the listed configuration: “—” means unavailable, not zero. DN, nominal inch size and outside diameter in mm are distinct quantities. Availability and component combinations are confirmed through the technical enquiry.
Lined clamp with one closing screwDM-CI03 · 9 configurationsDescription and technical table ↓

Characteristics
The EPDM liner introduces an elastomeric layer between pipe and clamp. It limits rigid contact and vibration transfer through the connection; acoustic performance depends on the complete installation.
Body material: Steel. Liner: EPDM.
Check clamping range, threaded connection and liner compression. The clamp must support the pipe without crushing the liner into a rigid bridge.
Use the configuration reference and size in your technical enquiry.
Configuration technical table
Dimensions are in mm where stated; G identifies the listed connection. B, H and other letters retain their configuration-specific definitions: request technical review for the dimensioned drawing. Plug dimensions are not pipe diameter.
| Reference | D [mm] | D ["] | G | B [mm] | H [mm] | b x s [mm] |
|---|---|---|---|---|---|---|
| DM-CI03-01 | 12 – 14 | 1/4 | M8 | 48 | 35 | 20 x 1,2 |
| DM-CI03-02 | 15 – 18 | 3/8 | M8 | 50 | 37 | 20 x 1,2 |
| DM-CI03-03 | 20 – 23 | 1/2 | M8 | 53 | 37 | 20 x 1,2 |
| DM-CI03-04 | 25 – 28 | 3/4 | M8 | 58 | 48 | 20 x 1,2 |
| DM-CI03-05 | 32 – 35 | 1 | M8 | 66 | 53 | 20 x 1,2 |
| DM-CI03-06 | 40 – 43 | 1 1/4 | M8 | 73 | 63 | 20 x 1,2 |
| DM-CI03-07 | 44 – 49 | 1 1/2 | M8 | 79 | 67 | 20 x 1,2 |
| DM-CI03-08 | 50 – 55 | — | M8 | 87 | 79 | 20 x 1,2 |
| DM-CI03-09 | 57 – 61 | 2 | M8 | 95 | 87 | 20 x 1,2 |
Tables checked on 18 November 2026. Values refer to the listed configuration: “—” means unavailable, not zero. DN, nominal inch size and outside diameter in mm are distinct quantities. Availability and component combinations are confirmed through the technical enquiry.
Pipe clamp finder
Select actual outside diameter, liner, material and connection. Missing dimensions are not inferred from a part number or DN.
Request technical review or a quotation
FAQ
How do lined and unlined pipe clamps differ?
A lined clamp introduces an elastomer between pipe and metal. An unlined clamp provides direct contact. A rubber insert alone does not guarantee a system noise-reduction value.
Should I select by DN or outside diameter?
Measure the actual pipe outside diameter and compare it with the clamping range. DN and nominal inch sizes must not automatically be converted into clamping diameter.
Does a heavy-duty clamp have the same capacity in every size?
No. Verification depends on clamp, screws, connection, rod, bracket, anchorage, orientation and system actions. Request data for the specific configuration.
Is a flue support clamp also a firestop collar?
No. Supporting a duct and providing a fire-resistant penetration seal are different functions with separate documentation and verification.
How do I prepare a technical enquiry?
Provide the family or sheet reference, pipe outside diameter and material, quantity, liner, connection, substrate, temperature, environment and loads or design requirements.
Related pages and documentation
Tables checked on 18 November 2026. Values refer to the listed configuration: “—” means unavailable, not zero. DN, nominal inch size and outside diameter in mm are distinct quantities. Availability and component combinations are confirmed through the technical enquiry.
Stainless pipe clamp · existing catalogue sheet · Anchors and fixings · Tecfi · clamps and fixings
Dueemme Sidol S.r.l. · Sesto San Giovanni, Milano · Supply for industrial customers and OEMs.