Dueemme Sidol · Pipe supports

Pipe clamp standards and selection

Technical guide to materials, liners, dimensions and documentation for pipe supports.

Acoustics and standards

DIN 4109-1:2018-01 concerns minimum sound-insulation requirements in buildings. It does not constitute generic certification of every rubber-lined clamp or assign a universal installed dB value.

For acoustic requirements request the report applicable to the configuration: pipe, clamp, liner, tightening, connection and structure. We do not publish a noise reduction inferred solely from liner material.

Mechanical verification

Define full-pipe weight, insulation, orientation, dynamic actions, expansion and stand-off distance. Verification must include clamp, connection, rod, bracket and anchorage. Dimensional tables identify designs and are not a load-capacity calculation.

Fixed points and sliding supports

The function depends on the support system and pipe design. Do not turn a sliding support into a fixed point by increasing tightening. Spacing and permitted movement must follow the pipe system.

Flue supports and firestops

A flue support clamp has a different function from a firestop collar for penetrations. This section does not assign a fire-resistance class to a service penetration.

DIN 4109-1:2018-01 · DIN Media ↗

Pipe clamp finder

Select actual outside diameter, liner, material and connection. Missing dimensions are not inferred from a part number or DN.

Request technical review or a quotation

The summary is transferred to the technical form for review and submission.

FAQ

How do lined and unlined pipe clamps differ?

A lined clamp introduces an elastomer between pipe and metal. An unlined clamp provides direct contact. A rubber insert alone does not guarantee a system noise-reduction value.

Should I select by DN or outside diameter?

Measure the actual pipe outside diameter and compare it with the clamping range. DN and nominal inch sizes must not automatically be converted into clamping diameter.

Does a heavy-duty clamp have the same capacity in every size?

No. Verification depends on clamp, screws, connection, rod, bracket, anchorage, orientation and system actions. Request data for the specific configuration.

Is a flue support clamp also a firestop collar?

No. Supporting a duct and providing a fire-resistant penetration seal are different functions with separate documentation and verification.

How do I prepare a technical enquiry?

Provide the family or sheet reference, pipe outside diameter and material, quantity, liner, connection, substrate, temperature, environment and loads or design requirements.

Related pages and documentation

Tables checked on 18 November 2026. Values refer to the listed configuration: “—” means unavailable, not zero. DN, nominal inch size and outside diameter in mm are distinct quantities. Availability and component combinations are confirmed through the technical enquiry.

Stainless pipe clamp · existing catalogue sheet · Anchors and fixings · Tecfi · clamps and fixings

Dueemme Sidol S.r.l. · Sesto San Giovanni, Milano · Supply for industrial customers and OEMs.

Dueemme Sidol
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.