Industrial fixings · Dueemme Sidol

Toggle and spring anchors

A toggle or spring element passes through the hole and opens behind the wall. Bearing area and clear cavity depth are essential parameters.

Tecfi BJ05 · Toggle and spring anchors
Family example · Tecfi BJ05

Features and selection criteria

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.

Designs, materials and substrates

This family contains 10 series or reference groups, with 26 catalogue rows. Series photographs help distinguish geometries and fixing methods; they do not necessarily represent every size in the range.

Documented materials

Steel

Substrates mentioned in the sources

Check the reference documentation.

This list describes the family and does not assign every substrate to every variant.

Information to define before selection

ParameterWhat to check
Load-bearing substrateMaterial type, strength, any cracking, useful thickness and hole conditions. Compatibility must be established for the selected design and size.
Fixing geometryTotal length, body or thread diameter and drill diameter are distinct parameters. Through-fixings must allow for fixture thickness and non-load-bearing layers.
Depth and distancesCompare hole depth, nominal or effective anchorage depth, edge distances and spacing. A deeper hole does not automatically increase fixing capacity.
Environment and exposureCheck material and coating of all components, temperature and service conditions. A2, A4 and HCR stainless designs require selection appropriate to the environment.
Loads and documentationDefine action directions and combinations and check the part-specific document. Dimensional data identify the part but do not replace a design verification.

Installation sequence to verify

  1. Check the access hole and cavity against the closed and opened element.
  2. Insert the toggle in the intended direction.
  3. Verify opening and bearing behind the wall.
  4. Tightening and threaded length must avoid board bending or crushing.

This sequence guides the reading of the instructions. Diameters, depths, equipment and tightening values remain those of the specific variant.

Series and technical tables

Tecfi BJ05 · Toggle and spring anchorsBJ05Tecfi · 6 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BJ05 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BJ05

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: drill Ø 12–18 mm; length 75–120 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BJ05 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BJ 25 04 07512SteelZinc plated75
Tecfi BJ 25 04 12012SteelZinc plated120
Tecfi BJ 05 04 08014SteelZinc plated80
Tecfi BJ 05 05 08014SteelZinc plated80
Tecfi BJ 05 05 12014SteelZinc plated120
Tecfi BJ 45 06 10018SteelZinc plated100

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BJ06 · Toggle and spring anchorsBJ06Tecfi · 4 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BJ06 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BJ06

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: drill Ø 12–18 mm; length 70–75 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BJ06 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BJ 26 04 07012SteelZinc plated70
Tecfi BJ 06 04 07014SteelZinc plated70
Tecfi BJ 06 05 07014SteelZinc plated70
Tecfi BJ 46 06 07518SteelZinc plated75

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BJ07 · Toggle and spring anchorsBJ07Tecfi · 4 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BJ07 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BJ07

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: drill Ø 12–18 mm; length 70–75 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BJ07 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BJ 27 04 07012SteelZinc plated70
Tecfi BJ 07 04 07014SteelZinc plated70
Tecfi BJ 07 05 07014SteelZinc plated70
Tecfi BJ 47 06 07518SteelZinc plated75

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BJ08 · Toggle and spring anchorsBJ08Tecfi · 4 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BJ08 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BJ08

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: drill Ø 12–18 mm; length 80–100 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BJ08 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BJ 28 04 08012SteelZinc plated80
Tecfi BJ 08 04 09514SteelZinc plated95
Tecfi BJ 08 05 10014SteelZinc plated100
Tecfi BJ 48 06 09518SteelZinc plated95

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BJ09 · Toggle and spring anchorsBJ09Tecfi · 1 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BJ09 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BJ09

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: drill Ø 14 mm; length 95 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BJ09 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BJ 09 04 09514SteelZinc plated95

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BK00 · Toggle and spring anchorsBK00Tecfi · 1 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BK00 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BK00

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BK00 · dimensional and installation characteristics
Part number and sourceMaterialFinishMisura M
Tecfi BK 00 06 000SteelZinc platedM6

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BK01 · Toggle and spring anchorsBK01Tecfi · 2 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BK01 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BK01

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: drill Ø 20 mm; length 75–100 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BK01 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BK 01 06 07516 / 17SteelZinc plated75
Tecfi BK 01 08 10020SteelZinc plated100

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BK02 · Toggle and spring anchorsBK02Tecfi · 2 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BK02 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BK02

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: drill Ø 20 mm; length 100 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BK02 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BK 02 06 10016 / 17SteelZinc plated100
Tecfi BK 02 08 10020SteelZinc plated100

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BK03 · Toggle and spring anchorsBK03Tecfi · 1 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BK03 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BK03

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: length 100 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BK03 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)MaterialFinishLength L (mm)
Tecfi BK 03 06 10016 / 17SteelZinc plated100

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi BK04 · Toggle and spring anchorsBK04Tecfi · 1 referencesElement bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.Full description and technical table ↓
Tecfi BK04 · Toggle and spring anchors
Series reference image · Tecfi

Series characteristics BK04

Element bearing transversely behind the wall. The hole must allow insertion and the cavity must permit opening and orientation of the end element.

Materials represented by the variants: Steel.

Documented series dimensions: length 75 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Specify insertion hole, wall thickness, rod length and opened-element clearance. An eye or hook alone does not constitute a certified lifting or fall-protection point.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi BK04 · dimensional and installation characteristics
Part number and sourceDrill Ø d₀ (mm)Length L (mm)
Tecfi BK 04 06 07516 / 1775

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Anchor finder

Search by part number or select declared characteristics. Missing data do not satisfy a dimensional filter.

Request technical review or a quotation

Select a finder reference or describe the application.

The summary is transferred to the contact form for your review and submission.

FAQ

How do I select an anchor?

Start with substrate, load and environment, then identify configuration, depth, distances and part-specific documentation. The finder selects catalogue references and does not perform a design check.

Does equal diameter mean equal capacity?

No. Geometry, material, anchorage and technical assessment may differ. Dimensional comparison does not establish technical equivalence or interchangeability.

Do all anchors have an ETA and CE marking?

These cannot be assigned to an entire category. Check the product documentation, scope and applicability to the specific size. An ETA link does not extend its assessment to other parts.

What information is needed for an enquiry?

Part number or family, quantity, substrate material and condition, thicknesses, fixing geometry, environment, actions and required documents. For resins, also specify temperature and hole conditions.

Sources and documentation

Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.

Tecfi · EJOT

Dueemme Sidol S.r.l. · Sesto San Giovanni, Milan · Supply for industrial customers and OEMs.

Dueemme Sidol
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.