Through-bolt expansion anchors
Tightening the nut draws the cone into the expansion clip inside the hole. Through-bolts normally allow installation through the fixture using the prescribed sequence.

Features and selection criteria
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Designs, materials and substrates
This family contains 13 series or reference groups, with 296 catalogue rows. Series photographs help distinguish geometries and fixing methods; they do not necessarily represent every size in the range.
Documented materials
Steel · Stainless A4 · Stainless A2 · HCR stainless
Substrates mentioned in the sources
Concrete · Cracked concrete
This list describes the family and does not assign every substrate to every variant.
Information to define before selection
| Parameter | What to check |
|---|---|
| Load-bearing substrate | Material type, strength, any cracking, useful thickness and hole conditions. Compatibility must be established for the selected design and size. |
| Fixing geometry | Total length, body or thread diameter and drill diameter are distinct parameters. Through-fixings must allow for fixture thickness and non-load-bearing layers. |
| Depth and distances | Compare hole depth, nominal or effective anchorage depth, edge distances and spacing. A deeper hole does not automatically increase fixing capacity. |
| Environment and exposure | Check material and coating of all components, temperature and service conditions. A2, A4 and HCR stainless designs require selection appropriate to the environment. |
| Loads and documentation | Define action directions and combinations and check the part-specific document. Dimensional data identify the part but do not replace a design verification. |
Installation sequence to verify
- Check substrate, drill diameter, depth and design distances.
- Drill and clean the hole as specified by the manufacturer.
- Insert the anchor to the depth of the selected configuration.
- Apply the specified installation torque: nut contact alone does not verify expansion.
This sequence guides the reading of the instructions. Diameters, depths, equipment and tightening values remain those of the specific variant.
Series and technical tables
AJE01Tecfi · 27 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics AJE01
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 8–20 mm; length 80–350 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Finish | Fixture thickness (mm) tfix | Part-specific documentation indicators |
|---|---|---|---|---|---|---|
| Tecfi AJE 01 08 080 | 8 | 80 | Steel | Zinc plated | 10 | ETA-CE R120 (TR 020) |
| Tecfi AJE 01 08 090 | 8 | 90 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) |
| Tecfi AJE 01 08 110 | 8 | 110 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) |
| Tecfi AJE 01 08 130 | 8 | 130 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) |
| Tecfi AJE 01 08 170 | 8 | 170 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) |
| Tecfi AJE 01 10 095 | 10 | 95 | Steel | Zinc plated | 10 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 10 105 | 10 | 105 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 10 125 | 10 | 125 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 10 145 | 10 | 145 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 10 185 | 10 | 185 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 10 245 | 10 | 245 | Steel | Zinc plated | 160 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 115 | 12 | 115 | Steel | Zinc plated | 10 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 125 | 12 | 125 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 145 | 12 | 145 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 165 | 12 | 165 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 205 | 12 | 205 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 225 | 12 | 225 | Steel | Zinc plated | 120 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 245 | 12 | 245 | Steel | Zinc plated | 140 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 265 | 12 | 265 | Steel | Zinc plated | 160 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 305 | 12 | 305 | Steel | Zinc plated | 200 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 12 350 | 12 | 350 | Steel | Zinc plated | 245 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 16 130 | 16 | 130 | Steel | Zinc plated | 5 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 16 145 | 16 | 145 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 16 165 | 16 | 165 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 16 225 | 16 | 225 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 20 170 | 20 | 170 | Steel | Zinc plated | 30 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 01 20 200 | 20 | 200 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) Sisma / Seismic |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
AJE31Tecfi · 27 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics AJE31
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 8–20 mm; length 80–350 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Finish | Fixture thickness (mm) tfix | Part-specific documentation indicators |
|---|---|---|---|---|---|---|
| Tecfi AJE 31 08 080 | 8 | 80 | Steel | Zinc plated | 10 | ETA-CE R120 (TR 020) |
| Tecfi AJE 31 08 090 | 8 | 90 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) |
| Tecfi AJE 31 08 110 | 8 | 110 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) |
| Tecfi AJE 31 08 130 | 8 | 130 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) |
| Tecfi AJE 31 08 170 | 8 | 170 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) |
| Tecfi AJE 31 10 095 | 10 | 95 | Steel | Zinc plated | 10 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 10 105 | 10 | 105 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 10 125 | 10 | 125 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 10 145 | 10 | 145 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 10 185 | 10 | 185 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 10 245 | 10 | 245 | Steel | Zinc plated | 160 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 115 | 12 | 115 | Steel | Zinc plated | 10 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 125 | 12 | 125 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 145 | 12 | 145 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 165 | 12 | 165 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 205 | 12 | 205 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 225 | 12 | 225 | Steel | Zinc plated | 120 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 245 | 12 | 245 | Steel | Zinc plated | 140 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 265 | 12 | 265 | Steel | Zinc plated | 160 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 305 | 12 | 305 | Steel | Zinc plated | 200 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 12 350 | 12 | 350 | Steel | Zinc plated | 245 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 16 130 | 16 | 130 | Steel | Zinc plated | 5 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 16 145 | 16 | 145 | Steel | Zinc plated | 20 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 16 165 | 16 | 165 | Steel | Zinc plated | 40 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 16 225 | 16 | 225 | Steel | Zinc plated | 100 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 20 170 | 20 | 170 | Steel | Zinc plated | 30 | ETA-CE R120 (TR 020) Sisma / Seismic |
| Tecfi AJE 31 20 200 | 20 | 200 | Steel | Zinc plated | 60 | ETA-CE R120 (TR 020) Sisma / Seismic |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ZJE01Tecfi · 44 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics ZJE01
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 6–20 mm; length 60–300 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Finish | Fixture thickness tfix,std (mm) | Part-specific documentation indicators |
|---|---|---|---|---|---|---|
| Tecfi ZJE 01 06 060 | 6 | 60 | Steel | Zinc plated | 2 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 06 080 | 6 | 80 | Steel | Zinc plated | 22 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 06 100 | 6 | 100 | Steel | Zinc plated | 42 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 06 120 | 6 | 120 | Steel | Zinc plated | 62 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 06 140 | 6 | 140 | Steel | Zinc plated | 82 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 06 160 | 6 | 160 | Steel | Zinc plated | 102 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 06 180 | 6 | 180 | Steel | Zinc plated | 122 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 08 060 | 8 | 60 | Steel | Zinc plated | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 08 075 | 8 | 75 | Steel | Zinc plated | 5 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 08 090 | 8 | 90 | Steel | Zinc plated | 20 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 08 115 | 8 | 115 | Steel | Zinc plated | 45 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 08 130 | 8 | 130 | Steel | Zinc plated | 60 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 08 165 | 8 | 165 | Steel | Zinc plated | 95 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 070 | 10 | 70 | Steel | Zinc plated | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 080 | 10 | 80 | Steel | Zinc plated | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 090 | 10 | 90 | Steel | Zinc plated | 10 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 110 | 10 | 110 | Steel | Zinc plated | 30 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 120 | 10 | 120 | Steel | Zinc plated | 40 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 150 | 10 | 150 | Steel | Zinc plated | 70 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 180 | 10 | 180 | Steel | Zinc plated | 100 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 10 210 | 10 | 210 | Steel | Zinc plated | 130 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 090 | 12 | 90 | Steel | Zinc plated | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 110 | 12 | 110 | Steel | Zinc plated | 18 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 125 | 12 | 125 | Steel | Zinc plated | 33 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 140 | 12 | 140 | Steel | Zinc plated | 48 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 160 | 12 | 160 | Steel | Zinc plated | 68 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 180 | 12 | 180 | Steel | Zinc plated | 88 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 200 | 12 | 200 | Steel | Zinc plated | 108 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 250 | 12 | 250 | Steel | Zinc plated | 158 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 280 | 12 | 280 | Steel | Zinc plated | 188 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 12 300 | 12 | 300 | Steel | Zinc plated | 208 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 14 120 | 14 | 120 | Steel | Zinc plated | 12 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 14 145 | 14 | 145 | Steel | Zinc plated | 37 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 14 170 | 14 | 170 | Steel | Zinc plated | 62 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 16 125 | 16 | 125 | Steel | Zinc plated | 3 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 16 145 | 16 | 145 | Steel | Zinc plated | 23 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 16 170 | 16 | 170 | Steel | Zinc plated | 48 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 16 220 | 16 | 220 | Steel | Zinc plated | 98 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 16 250 | 16 | 250 | Steel | Zinc plated | 128 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 16 280 | 16 | 280 | Steel | Zinc plated | 158 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 20 130 | 20 | 130 | Steel | Zinc plated | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 20 170 | 20 | 170 | Steel | Zinc plated | 23 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 20 220 | 20 | 220 | Steel | Zinc plated | 73 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 01 20 270 | 20 | 270 | Steel | Zinc plated | 123 | ETA-CE · EAD 330232-00-0601 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ZJE31Tecfi · 44 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics ZJE31
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 6–20 mm; length 60–300 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Finish | Fixture thickness tfix,std (mm) | Fixture thickness (mm) tfix, red | Part-specific documentation indicators |
|---|---|---|---|---|---|---|---|
| Tecfi ZJE 31 06 060 | 6 | 60 | Steel | Zinc plated | 2 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 06 080 | 6 | 80 | Steel | Zinc plated | 22 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 06 100 | 6 | 100 | Steel | Zinc plated | 42 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 06 120 | 6 | 120 | Steel | Zinc plated | 62 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 06 140 | 6 | 140 | Steel | Zinc plated | 82 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 06 160 | 6 | 160 | Steel | Zinc plated | 102 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 06 180 | 6 | 160 | Steel | Zinc plated | 122 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 08 060 | 8 | 60 | Steel | Zinc plated | — | 2 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 08 075 | 8 | 75 | Steel | Zinc plated | 4 | 17 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 08 090 | 8 | 90 | Steel | Zinc plated | 19 | 32 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 08 115 | 8 | 115 | Steel | Zinc plated | 44 | 57 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 08 130 | 8 | 130 | Steel | Zinc plated | 59 | 72 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 08 165 | 8 | 165 | Steel | Zinc plated | 94 | 107 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 070 | 10 | 70 | Steel | Zinc plated | — | 3 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 080 | 10 | 80 | Steel | Zinc plated | — | 13 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 090 | 10 | 90 | Steel | Zinc plated | 10 | 23 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 110 | 10 | 110 | Steel | Zinc plated | 30 | 43 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 120 | 10 | 120 | Steel | Zinc plated | 40 | 53 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 150 | 10 | 150 | Steel | Zinc plated | 70 | 83 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 180 | 10 | 180 | Steel | Zinc plated | 100 | 113 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 10 210 | 10 | 210 | Steel | Zinc plated | 130 | 143 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 090 | 12 | 90 | Steel | Zinc plated | — | 11 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 110 | 12 | 110 | Steel | Zinc plated | 16 | 31 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 125 | 12 | 125 | Steel | Zinc plated | 31 | 46 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 140 | 12 | 140 | Steel | Zinc plated | 46 | 61 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 160 | 12 | 160 | Steel | Zinc plated | 66 | 81 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 180 | 12 | 180 | Steel | Zinc plated | 86 | 101 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 200 | 12 | 200 | Steel | Zinc plated | 106 | 121 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 250 | 12 | 250 | Steel | Zinc plated | 156 | 171 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 280 | 12 | 280 | Steel | Zinc plated | 186 | 201 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 12 300 | 12 | 300 | Steel | Zinc plated | 206 | 221 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 14 120 | 14 | 120 | Steel | Zinc plated | 12 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 14 145 | 14 | 145 | Steel | Zinc plated | 37 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 14 170 | 14 | 170 | Steel | Zinc plated | 62 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 16 125 | 16 | 125 | Steel | Zinc plated | 1 | 20 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 16 145 | 16 | 145 | Steel | Zinc plated | 21 | 40 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 16 170 | 16 | 170 | Steel | Zinc plated | 46 | 65 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 16 220 | 16 | 220 | Steel | Zinc plated | 96 | 115 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 16 250 | 16 | 250 | Steel | Zinc plated | 126 | 145 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 16 280 | 16 | 280 | Steel | Zinc plated | 156 | 175 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 20 130 | 20 | 130 | Steel | Zinc plated | — | 7 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 20 170 | 20 | 170 | Steel | Zinc plated | 21 | 47 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 20 220 | 20 | 220 | Steel | Zinc plated | 71 | 97 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 31 20 270 | 20 | 270 | Steel | Zinc plated | 121 | 147 | ETA-CE · EAD 330232-00-0601 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ZJE71Tecfi · 19 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics ZJE71
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Stainless A4.
Documented series dimensions: nominal Ø 6–20 mm; length 60–220 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Fixture thickness tfix,std (mm) | Fixture thickness (mm) tfix, red | Part-specific documentation indicators |
|---|---|---|---|---|---|---|
| Tecfi ZJE 71 06 060 | 6 | 60 | Acciaio Inox A4 | 2 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 06 080 | 6 | 80 | Acciaio Inox A4 | 22 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 08 075 | 8 | 75 | Acciaio Inox A4 | 5 | 17 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 08 090 | 8 | 90 | Acciaio Inox A4 | 20 | 32 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 08 115 | 8 | 115 | Acciaio Inox A4 | 45 | 57 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 10 070 | 10 | 70 | Acciaio Inox A4 | — | 3 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 10 090 | 10 | 90 | Acciaio Inox A4 | 10 | 23 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 10 120 | 10 | 120 | Acciaio Inox A4 | 40 | 53 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 10 150 | 10 | 150 | Acciaio Inox A4 | 70 | 83 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 12 090 | 12 | 90 | Acciaio Inox A4 | — | 13 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 12 110 | 12 | 110 | Acciaio Inox A4 | 18 | 33 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 12 140 | 12 | 140 | Acciaio Inox A4 | 48 | 63 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 12 180 | 12 | 180 | Acciaio Inox A4 | 88 | 103 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 16 090 | 16 | 90 | Acciaio Inox A4 | — | — | — |
| Tecfi ZJE 71 16 125 | 16 | 125 | Acciaio Inox A4 | 3 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 16 145 | 16 | 145 | Acciaio Inox A4 | 23 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 16 170 | 16 | 170 | Acciaio Inox A4 | 48 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 20 170 | 20 | 170 | Acciaio Inox A4 | 23 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 71 20 220 | 20 | 220 | Acciaio Inox A4 | 73 | — | ETA-CE · EAD 330232-00-0601 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ZJE81Tecfi · 19 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics ZJE81
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Stainless A4.
Documented series dimensions: nominal Ø 6–20 mm; length 60–220 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Fixture thickness tfix,std (mm) | Fixture thickness (mm) tfix, red | Part-specific documentation indicators |
|---|---|---|---|---|---|---|
| Tecfi ZJE 81 06 060 | 6 | 60 | Acciaio Inox A4 | 2 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 06 080 | 6 | 80 | Acciaio Inox A4 | 22 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 08 075 | 8 | 75 | Acciaio Inox A4 | 4 | 17 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 08 090 | 8 | 90 | Acciaio Inox A4 | 19 | 32 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 08 115 | 8 | 115 | Acciaio Inox A4 | 44 | 57 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 10 070 | 10 | 70 | Acciaio Inox A4 | — | 3 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 10 090 | 10 | 90 | Acciaio Inox A4 | 10 | 23 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 10 120 | 10 | 120 | Acciaio Inox A4 | 40 | 53 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 10 150 | 10 | 150 | Acciaio Inox A4 | 70 | 83 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 12 090 | 12 | 90 | Acciaio Inox A4 | — | 11 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 12 110 | 12 | 110 | Acciaio Inox A4 | 16 | 31 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 12 140 | 12 | 140 | Acciaio Inox A4 | 46 | 61 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 12 180 | 12 | 180 | Acciaio Inox A4 | 86 | 101 | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 16 090 | 16 | 90 | Acciaio Inox A4 | — | — | — |
| Tecfi ZJE 81 16 125 | 16 | 125 | Acciaio Inox A4 | 1 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 16 145 | 16 | 145 | Acciaio Inox A4 | 21 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 16 170 | 16 | 170 | Acciaio Inox A4 | 46 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 20 170 | 20 | 170 | Acciaio Inox A4 | 21 | — | ETA-CE · EAD 330232-00-0601 |
| Tecfi ZJE 81 20 220 | 20 | 220 | Acciaio Inox A4 | 71 | — | ETA-CE · EAD 330232-00-0601 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
AJ04Tecfi · 23 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics AJ04
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 8–24 mm; length 70–310 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Finish | Fixture thickness (mm) tfix |
|---|---|---|---|---|---|
| Tecfi AJ 04 08 075 | 8 | 75 | Steel | Zinc plated | 10 |
| Tecfi AJ 04 08 095 | 8 | 95 | Steel | Zinc plated | 30 |
| Tecfi AJ 04 08 115 | 8 | 115 | Steel | Zinc plated | 50 |
| Tecfi AJ 04 08 135 | 8 | 135 | Steel | Zinc plated | 70 |
| Tecfi AJ 04 10 070 | 10 | 70 | Steel | Zinc plated | 5 |
| Tecfi AJ 04 10 080 | 10 | 80 | Steel | Zinc plated | 5 |
| Tecfi AJ 04 10 090 | 10 | 90 | Steel | Zinc plated | 15 |
| Tecfi AJ 04 10 100 | 10 | 100 | Steel | Zinc plated | 25 |
| Tecfi AJ 04 10 120 | 10 | 120 | Steel | Zinc plated | 45 |
| Tecfi AJ 04 10 140 | 10 | 140 | Steel | Zinc plated | 65 |
| Tecfi AJ 04 12 080 | 12 | 80 | Steel | Zinc plated | 5 |
| Tecfi AJ 04 12 095 | 12 | 95 | Steel | Zinc plated | 5 |
| Tecfi AJ 04 12 110 | 12 | 110 | Steel | Zinc plated | 20 |
| Tecfi AJ 04 12 130 | 12 | 130 | Steel | Zinc plated | 40 |
| Tecfi AJ 04 12 160 | 12 | 160 | Steel | Zinc plated | 70 |
| Tecfi AJ 04 16 090 | 16 | 90 | — | — | 5 |
| Tecfi AJ 04 16 125 | 16 | 125 | Steel | Zinc plated | 5 |
| Tecfi AJ 04 16 145 | 16 | 145 | Steel | Zinc plated | 25 |
| Tecfi AJ 04 16 180 | 16 | 180 | Steel | Zinc plated | 60 |
| Tecfi AJ 04 24 160 | 24 | 160 | Steel | Zinc plated | 10 |
| Tecfi AJ 04 24 200 | 24 | 200 | Steel | Zinc plated | 30 |
| Tecfi AJ 04 24 260 | 24 | 260 | Steel | Zinc plated | 90 |
| Tecfi AJ 04 24 310 | 24 | 310 | Steel | Zinc plated | 140 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
AJ02Tecfi · 10 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics AJ02
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Stainless A2.
Documented series dimensions: nominal Ø 6–12 mm; length 60–180 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Nominal Ø dnom (mm) | Length L (mm) | Material | Finish | Fixture thickness (mm) tfix |
|---|---|---|---|---|---|
| Tecfi AJ 02 06 100 | 6 | 100 | Acciaio / Acciaio Inox A2 | Zinc plated | 50 |
| Tecfi AJ 02 08 060 | 8 | 60 | Acciaio / Acciaio Inox A2 | Zinc plated | 5 |
| Tecfi AJ 02 08 080 | 8 | 80 | Acciaio / Acciaio Inox A2 | Zinc plated | 25 |
| Tecfi AJ 02 08 115 | 8 | 115 | Acciaio / Acciaio Inox A2 | Zinc plated | 60 |
| Tecfi AJ 02 08 135 | 8 | 135 | Acciaio / Acciaio Inox A2 | Zinc plated | 80 |
| Tecfi AJ 02 10 070 | 10 | 70 | Acciaio / Acciaio Inox A2 | Zinc plated | 5 |
| Tecfi AJ 02 10 140 | 10 | 140 | Acciaio / Acciaio Inox A2 | Zinc plated | 75 |
| Tecfi AJ 02 12 100 | 12 | 100 | Acciaio / Acciaio Inox A2 | Zinc plated | 20 |
| Tecfi AJ 02 12 140 | 12 | 140 | Acciaio / Acciaio Inox A2 | Zinc plated | 60 |
| Tecfi AJ 02 12 180 | 12 | 180 | Acciaio / Acciaio Inox A2 | Zinc plated | 100 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
BA-E Plus HCREJOT · 6 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics BA-E Plus HCR
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: HCR stainless.
Documented series dimensions: length 45–112 mm; thread Ø 8–10 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Length (mm) | Thread Ø (mm) | Fixture thickness B ≥ (mm) | Hole depth (mm), as stated by the source | Anchorage depth (mm) | HEX |
|---|---|---|---|---|---|---|
| EJOT 9650006308 | 57.0 | 8.0 | 5 | 47 | 35 | 13.0 |
| EJOT 9650006310 | 75.0 | 8.0 | 23.0 | 47/60 | 35/48 | 13.0 |
| EJOT 9650006312 | 45.0 | 8.0 | 43/30 | 47/60 | 35/80 | 13.0 |
| EJOT 9650006323 | 72.0 | 10.0 | 10.0 | 55 | 40 | 17.0 |
| EJOT 9650006325 | 92.0 | 10.0 | 30/10 | 55/75 | 40/60 | 17.0 |
| EJOT 9650006327 | 112.0 | 10.0 | 50.0 | 55/75 | 40/60 | 17.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
BA-V PlusEJOT · 21 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics BA-V Plus
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: length 72–178 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Length (mm) | Thread Ø (mm) | Fixture thickness B ≥ (mm) | Hole depth (mm), as stated by the source | Anchorage depth (mm) | Wrench size (mm) | Effective anchorage depth h ef ≥ mm |
|---|---|---|---|---|---|---|---|
| EJOT 9650001310 | 75.0 | 8.0 | 23/10 | 47/60 | 35/48 | 13.0 | 35.0 |
| EJOT 9650001312 | 95.0 | 8.0 | 43/30 | 47/60 | 35/48 | 13.0 | 35.0 |
| EJOT 9650001314 | 115.0 | 8.0 | 63.0 | 47 | — | — | 35.0 |
| EJOT 9650001316 | 150.0 | 8.0 | 98.0 | 47 | — | — | 35.0 |
| EJOT 9650001323 | 72.0 | 10.0 | 10.0 | 55 | 40 | 17.0 | 40.0 |
| EJOT 9650001325 | 92.0 | 10.0 | 10.0 | 55/75 | 40/60 | 17.0 | 40.0 |
| EJOT 9650001326 | 102.0 | 10.0 | 40.0 | 55/75 | 40/60 | 17.0 | — |
| EJOT 9650001327 | 112.0 | 10.0 | 50.0 | — | — | — | 40.0 |
| EJOT 9650001329 | 132.0 | 10.0 | 70.0 | — | — | — | 40.0 |
| EJOT 9650001331 | 162.0 | 10.0 | 100.0 | — | — | — | 40.0 |
| EJOT 9650001338 | 88.0 | 12.0 | 10.0 | 70 | 50 | 19.0 | 50.0 |
| EJOT 9650001340 | 103.0 | 12.0 | 25.0 | 70/90 | 50/70 | 19.0 | 50.0 |
| EJOT 9650001342 | 118.0 | 12.0 | 40.0 | 70/90 | 50/70 | 19.0 | 50.0 |
| EJOT 9650001343 | 128.0 | 12.0 | 50.0 | — | — | — | 50.0 |
| EJOT 9650001345 | 148.0 | 12.0 | 70.0 | — | — | — | 50.0 |
| EJOT 9650001346 | 163.0 | 12.0 | 85.0 | — | — | — | 50.0 |
| EJOT 9650001347 | 178.0 | 12.0 | 100.0 | — | — | — | 50.0 |
| EJOT 9650001357 | 123.0 | 16.0 | 5.0 | — | — | — | 85.0 |
| EJOT 9650001359 | 138.0 | 16.0 | 20.0 | 110 | 85 | 24.0 | 85.0 |
| EJOT 9650001362 | 168.0 | 16.0 | 50.0 | 110 | 85 | 24.0 | 85.0 |
| EJOT 9650001363 | 178.0 | 16.0 | 60.0 | — | — | — | 85.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
BA-F PlusEJOT · 21 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics BA-F Plus
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: length 72–178 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Thread Ø (mm) | Length (mm) | Hole depth ≤ (mm), source wording | Fixture thickness B ≥ (mm) | Effective anchorage depth h ef ≥ mm |
|---|---|---|---|---|---|
| EJOT 9650003310 | 8.0 | 75.0 | 47.0 | 23.0 | 35.0 |
| EJOT 9650003312 | 8.0 | 95.0 | 47.0 | 43.0 | 35.0 |
| EJOT 9650003314 | 8.0 | 115.0 | 47.0 | 63.0 | 35.0 |
| EJOT 9650003316 | 8.0 | 150.0 | 47.0 | 98.0 | 35.0 |
| EJOT 9650003323 | 10.0 | 72.0 | 55.0 | 10.0 | 40.0 |
| EJOT 9650003325 | 10.0 | 92.0 | 55.0 | 30.0 | 40.0 |
| EJOT 9650003326 | 10.0 | 102.0 | 55.0 | 40.0 | 40.0 |
| EJOT 9650003327 | 10.0 | 112.0 | 55.0 | 50.0 | 40.0 |
| EJOT 9650003329 | 10.0 | 132.0 | 55.0 | 70.0 | 40.0 |
| EJOT 9650003331 | 10.0 | 162.0 | 55.0 | 100.0 | 40.0 |
| EJOT 9650003338 | 12.0 | 88.0 | 70.0 | 10.0 | 50.0 |
| EJOT 9650003340 | 12.0 | 103.0 | 70.0 | 25.0 | 50.0 |
| EJOT 9650003342 | 12.0 | 118.0 | 70.0 | 40.0 | 50.0 |
| EJOT 9650003343 | 12.0 | 128.0 | 70.0 | 50.0 | 50.0 |
| EJOT 9650003345 | 12.0 | 148.0 | 70.0 | 70.0 | 50.0 |
| EJOT 9650003346 | 12.0 | 163.0 | 70.0 | 85.0 | 50.0 |
| EJOT 9650003347 | 12.0 | 178.0 | 70.0 | 100.0 | 50.0 |
| EJOT 9650003357 | 16.0 | 123.0 | 110.0 | 5.0 | 85.0 |
| EJOT 9650003359 | 16.0 | 138.0 | 110.0 | 20.0 | 85.0 |
| EJOT 9650003362 | 16.0 | 168.0 | 110.0 | 50.0 | 85.0 |
| EJOT 9650003363 | 16.0 | 178.0 | 110.0 | 60.0 | 85.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
BA-E PlusEJOT · 21 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics BA-E Plus
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Stainless A4, HCR stainless.
Documented series dimensions: length 72–178 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Length (mm) | Thread Ø (mm) | Hole depth (mm), as stated by the source | Anchorage depth (mm) | Wrench size (mm) | Hole depth ≤ (mm), source wording | Fixture thickness B ≥ (mm) | Effective anchorage depth h ef ≥ mm |
|---|---|---|---|---|---|---|---|---|
| EJOT 9650005310 | 75.0 | 8.0 | 47/60 | 35/48 | 13.0 | 47.0 | 23.0 | 35.0 |
| EJOT 9650005312 | 95.0 | 8.0 | 47/60 | 35/48 | 13.0 | 47.0 | 43.0 | 35.0 |
| EJOT 9650005314 | 115.0 | 8.0 | — | — | — | 47.0 | 63.0 | 35.0 |
| EJOT 9650005316 | 150.0 | 8.0 | — | — | — | 47.0 | 98.0 | 35.0 |
| EJOT 9650005323 | 72.0 | 10.0 | 35 | 40 | 17.0 | 55.0 | 10.0 | 40.0 |
| EJOT 9650005325 | 92.0 | 10.0 | 55/75 | 40/60 | 17.0 | 55.0 | 30.0 | 40.0 |
| EJOT 9650005326 | 102.0 | 10.0 | 55/75 | 40/60 | 17.0 | 55.0 | 40.0 | 40.0 |
| EJOT 9650005327 | 112.0 | 10.0 | — | — | — | 55.0 | 50.0 | 40.0 |
| EJOT 9650005329 | 132.0 | 10.0 | — | — | — | 55.0 | 70.0 | 40.0 |
| EJOT 9650005331 | 162.0 | 10.0 | — | — | — | 55.0 | 100.0 | 40.0 |
| EJOT 9650005338 | 88.0 | 12.0 | 70 | 50 | 19.0 | 70.0 | 10.0 | 50.0 |
| EJOT 9650005340 | 103.0 | 12.0 | 70/90 | 50/70 | 19.0 | 70.0 | 25.0 | 50.0 |
| EJOT 9650005342 | 118.0 | 12.0 | 70/90 | 50/70 | 19.0 | 70.0 | 40.0 | 50.0 |
| EJOT 9650005343 | 128.0 | 12.0 | — | — | — | 70.0 | 50.0 | 50.0 |
| EJOT 9650005345 | 148.0 | 12.0 | — | — | — | 70.0 | 70.0 | 50.0 |
| EJOT 9650005346 | 163.0 | 12.0 | — | — | — | 70.0 | 85.0 | 50.0 |
| EJOT 9650005347 | 178.0 | 12.0 | — | — | — | 70.0 | 100.0 | 50.0 |
| EJOT 9650005357 | 123.0 | 16.0 | — | — | — | 110.0 | 5.0 | 85.0 |
| EJOT 9650005359 | 138.0 | 16.0 | 110 | 85 | 24.0 | 110.0 | 20.0 | 85.0 |
| EJOT 9650005362 | 168.0 | 16.0 | 110 | 85 | 24.0 | 110.0 | 50.0 | 85.0 |
| EJOT 9650005363 | 178.0 | 16.0 | — | — | — | 110.0 | 60.0 | 85.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
BA-C NCEJOT · 14 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓

Series characteristics BA-C NC
Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.
Materials represented by the variants: Steel.
Documented series dimensions: length 75–175 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.
Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Length (mm) | Thread Ø (mm) | Hole depth ≤ (mm), source wording | Drill bit Ø (mm) | Fixture thickness B ≥ (mm) | Effective anchorage depth h ef ≥ mm |
|---|---|---|---|---|---|---|
| EJOT 9650007202 | 75.0 | 8.0 | 63.0 | 8.0 | 10.0 | 43.0 |
| EJOT 9650007203 | 95.0 | 8.0 | 63.0 | 8.0 | 30.0 | 43.0 |
| EJOT 9650007205 | 115.0 | 8.0 | 63.0 | 8.0 | 50.0 | 43.0 |
| EJOT 9650007208 | 85.0 | 10.0 | 69.0 | 10.0 | 10.0 | 50.0 |
| EJOT 9650007209 | 95.0 | 10.0 | 69.0 | 10.0 | 20.0 | 50.0 |
| EJOT 9650007210 | 105.0 | 10.0 | 69.0 | 10.0 | 30.0 | 50.0 |
| EJOT 9650007211 | 125.0 | 10.0 | 69.0 | 10.0 | 50.0 | 50.0 |
| EJOT 9650007212 | 110.0 | 12.0 | 92.0 | 12.0 | 10.0 | 70.0 |
| EJOT 9650007213 | 120.0 | 12.0 | 92.0 | 12.0 | 20.0 | 70.0 |
| EJOT 9650007214 | 130.0 | 12.0 | 92.0 | 12.0 | 30.0 | 70.0 |
| EJOT 9650007215 | 150.0 | 12.0 | 92.0 | 12.0 | 50.0 | 70.0 |
| EJOT 9650007217 | 135.0 | 16.0 | 109.0 | 16.0 | 10.0 | 85.0 |
| EJOT 9650007219 | 145.0 | 16.0 | 109.0 | 16.0 | 20.0 | 85.0 |
| EJOT 9650007220 | 175.0 | 16.0 | 109.0 | 16.0 | 50.0 | 85.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
Anchor finder
Search by part number or select declared characteristics. Missing data do not satisfy a dimensional filter.
Request technical review or a quotation
Select a finder reference or describe the application.
FAQ
How do I select an anchor?
Start with substrate, load and environment, then identify configuration, depth, distances and part-specific documentation. The finder selects catalogue references and does not perform a design check.
Does equal diameter mean equal capacity?
No. Geometry, material, anchorage and technical assessment may differ. Dimensional comparison does not establish technical equivalence or interchangeability.
Do all anchors have an ETA and CE marking?
These cannot be assigned to an entire category. Check the product documentation, scope and applicability to the specific size. An ETA link does not extend its assessment to other parts.
What information is needed for an enquiry?
Part number or family, quantity, substrate material and condition, thicknesses, fixing geometry, environment, actions and required documents. For resins, also specify temperature and hole conditions.
Sources and documentation
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Dueemme Sidol S.r.l. · Sesto San Giovanni, Milan · Supply for industrial customers and OEMs.