Industrial fixings · Dueemme Sidol

Through-bolt expansion anchors

Tightening the nut draws the cone into the expansion clip inside the hole. Through-bolts normally allow installation through the fixture using the prescribed sequence.

Tecfi AJE01 · Through-bolt expansion anchors
Family example · Tecfi AJE01

Features and selection criteria

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.

Designs, materials and substrates

This family contains 13 series or reference groups, with 296 catalogue rows. Series photographs help distinguish geometries and fixing methods; they do not necessarily represent every size in the range.

Documented materials

Steel · Stainless A4 · Stainless A2 · HCR stainless

Substrates mentioned in the sources

Concrete · Cracked concrete

This list describes the family and does not assign every substrate to every variant.

Information to define before selection

ParameterWhat to check
Load-bearing substrateMaterial type, strength, any cracking, useful thickness and hole conditions. Compatibility must be established for the selected design and size.
Fixing geometryTotal length, body or thread diameter and drill diameter are distinct parameters. Through-fixings must allow for fixture thickness and non-load-bearing layers.
Depth and distancesCompare hole depth, nominal or effective anchorage depth, edge distances and spacing. A deeper hole does not automatically increase fixing capacity.
Environment and exposureCheck material and coating of all components, temperature and service conditions. A2, A4 and HCR stainless designs require selection appropriate to the environment.
Loads and documentationDefine action directions and combinations and check the part-specific document. Dimensional data identify the part but do not replace a design verification.

Installation sequence to verify

  1. Check substrate, drill diameter, depth and design distances.
  2. Drill and clean the hole as specified by the manufacturer.
  3. Insert the anchor to the depth of the selected configuration.
  4. Apply the specified installation torque: nut contact alone does not verify expansion.

This sequence guides the reading of the instructions. Diameters, depths, equipment and tightening values remain those of the specific variant.

Series and technical tables

Tecfi AJE01 · Through-bolt expansion anchorsAJE01Tecfi · 27 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi AJE01 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics AJE01

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 8–20 mm; length 80–350 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi AJE01 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfixPart-specific documentation indicators
Tecfi AJE 01 08 080880SteelZinc plated10ETA-CE
R120 (TR 020)
Tecfi AJE 01 08 090890SteelZinc plated20ETA-CE
R120 (TR 020)
Tecfi AJE 01 08 1108110SteelZinc plated40ETA-CE
R120 (TR 020)
Tecfi AJE 01 08 1308130SteelZinc plated60ETA-CE
R120 (TR 020)
Tecfi AJE 01 08 1708170SteelZinc plated100ETA-CE
R120 (TR 020)
Tecfi AJE 01 10 0951095SteelZinc plated10ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 10 10510105SteelZinc plated20ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 10 12510125SteelZinc plated40ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 10 14510145SteelZinc plated60ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 10 18510185SteelZinc plated100ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 10 24510245SteelZinc plated160ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 11512115SteelZinc plated10ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 12512125SteelZinc plated20ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 14512145SteelZinc plated40ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 16512165SteelZinc plated60ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 20512205SteelZinc plated100ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 22512225SteelZinc plated120ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 24512245SteelZinc plated140ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 26512265SteelZinc plated160ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 30512305SteelZinc plated200ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 12 35012350SteelZinc plated245ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 16 13016130SteelZinc plated5ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 16 14516145SteelZinc plated20ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 16 16516165SteelZinc plated40ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 16 22516225SteelZinc plated100ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 20 17020170SteelZinc plated30ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 01 20 20020200SteelZinc plated60ETA-CE
R120 (TR 020)
Sisma / Seismic

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi AJE31 · Through-bolt expansion anchorsAJE31Tecfi · 27 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi AJE31 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics AJE31

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 8–20 mm; length 80–350 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi AJE31 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfixPart-specific documentation indicators
Tecfi AJE 31 08 080880SteelZinc plated10ETA-CE
R120 (TR 020)
Tecfi AJE 31 08 090890SteelZinc plated20ETA-CE
R120 (TR 020)
Tecfi AJE 31 08 1108110SteelZinc plated40ETA-CE
R120 (TR 020)
Tecfi AJE 31 08 1308130SteelZinc plated60ETA-CE
R120 (TR 020)
Tecfi AJE 31 08 1708170SteelZinc plated100ETA-CE
R120 (TR 020)
Tecfi AJE 31 10 0951095SteelZinc plated10ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 10 10510105SteelZinc plated20ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 10 12510125SteelZinc plated40ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 10 14510145SteelZinc plated60ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 10 18510185SteelZinc plated100ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 10 24510245SteelZinc plated160ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 11512115SteelZinc plated10ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 12512125SteelZinc plated20ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 14512145SteelZinc plated40ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 16512165SteelZinc plated60ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 20512205SteelZinc plated100ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 22512225SteelZinc plated120ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 24512245SteelZinc plated140ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 26512265SteelZinc plated160ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 30512305SteelZinc plated200ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 12 35012350SteelZinc plated245ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 16 13016130SteelZinc plated5ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 16 14516145SteelZinc plated20ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 16 16516165SteelZinc plated40ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 16 22516225SteelZinc plated100ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 20 17020170SteelZinc plated30ETA-CE
R120 (TR 020)
Sisma / Seismic
Tecfi AJE 31 20 20020200SteelZinc plated60ETA-CE
R120 (TR 020)
Sisma / Seismic

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi ZJE01 · Through-bolt expansion anchorsZJE01Tecfi · 44 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi ZJE01 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics ZJE01

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 6–20 mm; length 60–300 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi ZJE01 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness tfix,std (mm)Part-specific documentation indicators
Tecfi ZJE 01 06 060660SteelZinc plated2ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 06 080680SteelZinc plated22ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 06 1006100SteelZinc plated42ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 06 1206120SteelZinc plated62ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 06 1406140SteelZinc plated82ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 06 1606160SteelZinc plated102ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 06 1806180SteelZinc plated122ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 08 060860SteelZinc plated—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 08 075875SteelZinc plated5ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 08 090890SteelZinc plated20ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 08 1158115SteelZinc plated45ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 08 1308130SteelZinc plated60ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 08 1658165SteelZinc plated95ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 0701070SteelZinc plated—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 0801080SteelZinc plated—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 0901090SteelZinc plated10ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 11010110SteelZinc plated30ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 12010120SteelZinc plated40ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 15010150SteelZinc plated70ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 18010180SteelZinc plated100ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 10 21010210SteelZinc plated130ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 0901290SteelZinc plated—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 11012110SteelZinc plated18ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 12512125SteelZinc plated33ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 14012140SteelZinc plated48ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 16012160SteelZinc plated68ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 18012180SteelZinc plated88ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 20012200SteelZinc plated108ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 25012250SteelZinc plated158ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 28012280SteelZinc plated188ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 12 30012300SteelZinc plated208ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 14 12014120SteelZinc plated12ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 14 14514145SteelZinc plated37ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 14 17014170SteelZinc plated62ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 16 12516125SteelZinc plated3ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 16 14516145SteelZinc plated23ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 16 17016170SteelZinc plated48ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 16 22016220SteelZinc plated98ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 16 25016250SteelZinc plated128ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 16 28016280SteelZinc plated158ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 20 13020130SteelZinc plated—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 20 17020170SteelZinc plated23ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 20 22020220SteelZinc plated73ETA-CE · EAD 330232-00-0601
Tecfi ZJE 01 20 27020270SteelZinc plated123ETA-CE · EAD 330232-00-0601

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi ZJE31 · Through-bolt expansion anchorsZJE31Tecfi · 44 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi ZJE31 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics ZJE31

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 6–20 mm; length 60–300 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi ZJE31 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness tfix,std (mm)Fixture thickness (mm) tfix, redPart-specific documentation indicators
Tecfi ZJE 31 06 060660SteelZinc plated2—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 06 080680SteelZinc plated22—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 06 1006100SteelZinc plated42—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 06 1206120SteelZinc plated62—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 06 1406140SteelZinc plated82—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 06 1606160SteelZinc plated102—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 06 1806160SteelZinc plated122—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 08 060860SteelZinc plated—2ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 08 075875SteelZinc plated417ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 08 090890SteelZinc plated1932ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 08 1158115SteelZinc plated4457ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 08 1308130SteelZinc plated5972ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 08 1658165SteelZinc plated94107ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 0701070SteelZinc plated—3ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 0801080SteelZinc plated—13ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 0901090SteelZinc plated1023ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 11010110SteelZinc plated3043ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 12010120SteelZinc plated4053ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 15010150SteelZinc plated7083ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 18010180SteelZinc plated100113ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 10 21010210SteelZinc plated130143ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 0901290SteelZinc plated—11ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 11012110SteelZinc plated1631ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 12512125SteelZinc plated3146ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 14012140SteelZinc plated4661ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 16012160SteelZinc plated6681ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 18012180SteelZinc plated86101ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 20012200SteelZinc plated106121ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 25012250SteelZinc plated156171ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 28012280SteelZinc plated186201ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 12 30012300SteelZinc plated206221ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 14 12014120SteelZinc plated12—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 14 14514145SteelZinc plated37—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 14 17014170SteelZinc plated62—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 16 12516125SteelZinc plated120ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 16 14516145SteelZinc plated2140ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 16 17016170SteelZinc plated4665ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 16 22016220SteelZinc plated96115ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 16 25016250SteelZinc plated126145ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 16 28016280SteelZinc plated156175ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 20 13020130SteelZinc plated—7ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 20 17020170SteelZinc plated2147ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 20 22020220SteelZinc plated7197ETA-CE · EAD 330232-00-0601
Tecfi ZJE 31 20 27020270SteelZinc plated121147ETA-CE · EAD 330232-00-0601

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi ZJE71 · Through-bolt expansion anchorsZJE71Tecfi · 19 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi ZJE71 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics ZJE71

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Stainless A4.

Documented series dimensions: nominal Ø 6–20 mm; length 60–220 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi ZJE71 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFixture thickness tfix,std (mm)Fixture thickness (mm) tfix, redPart-specific documentation indicators
Tecfi ZJE 71 06 060660Acciaio Inox A42—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 06 080680Acciaio Inox A422—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 08 075875Acciaio Inox A4517ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 08 090890Acciaio Inox A42032ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 08 1158115Acciaio Inox A44557ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 10 0701070Acciaio Inox A4—3ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 10 0901090Acciaio Inox A41023ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 10 12010120Acciaio Inox A44053ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 10 15010150Acciaio Inox A47083ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 12 0901290Acciaio Inox A4—13ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 12 11012110Acciaio Inox A41833ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 12 14012140Acciaio Inox A44863ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 12 18012180Acciaio Inox A488103ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 16 0901690Acciaio Inox A4———
Tecfi ZJE 71 16 12516125Acciaio Inox A43—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 16 14516145Acciaio Inox A423—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 16 17016170Acciaio Inox A448—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 20 17020170Acciaio Inox A423—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 71 20 22020220Acciaio Inox A473—ETA-CE · EAD 330232-00-0601

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi ZJE81 · Through-bolt expansion anchorsZJE81Tecfi · 19 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi ZJE81 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics ZJE81

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Stainless A4.

Documented series dimensions: nominal Ø 6–20 mm; length 60–220 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi ZJE81 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFixture thickness tfix,std (mm)Fixture thickness (mm) tfix, redPart-specific documentation indicators
Tecfi ZJE 81 06 060660Acciaio Inox A42—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 06 080680Acciaio Inox A422—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 08 075875Acciaio Inox A4417ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 08 090890Acciaio Inox A41932ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 08 1158115Acciaio Inox A44457ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 10 0701070Acciaio Inox A4—3ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 10 0901090Acciaio Inox A41023ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 10 12010120Acciaio Inox A44053ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 10 15010150Acciaio Inox A47083ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 12 0901290Acciaio Inox A4—11ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 12 11012110Acciaio Inox A41631ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 12 14012140Acciaio Inox A44661ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 12 18012180Acciaio Inox A486101ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 16 0901690Acciaio Inox A4———
Tecfi ZJE 81 16 12516125Acciaio Inox A41—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 16 14516145Acciaio Inox A421—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 16 17016170Acciaio Inox A446—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 20 17020170Acciaio Inox A421—ETA-CE · EAD 330232-00-0601
Tecfi ZJE 81 20 22020220Acciaio Inox A471—ETA-CE · EAD 330232-00-0601

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi AJ04 · Through-bolt expansion anchorsAJ04Tecfi · 23 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi AJ04 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics AJ04

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 8–24 mm; length 70–310 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi AJ04 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfix
Tecfi AJ 04 08 075875SteelZinc plated10
Tecfi AJ 04 08 095895SteelZinc plated30
Tecfi AJ 04 08 1158115SteelZinc plated50
Tecfi AJ 04 08 1358135SteelZinc plated70
Tecfi AJ 04 10 0701070SteelZinc plated5
Tecfi AJ 04 10 0801080SteelZinc plated5
Tecfi AJ 04 10 0901090SteelZinc plated15
Tecfi AJ 04 10 10010100SteelZinc plated25
Tecfi AJ 04 10 12010120SteelZinc plated45
Tecfi AJ 04 10 14010140SteelZinc plated65
Tecfi AJ 04 12 0801280SteelZinc plated5
Tecfi AJ 04 12 0951295SteelZinc plated5
Tecfi AJ 04 12 11012110SteelZinc plated20
Tecfi AJ 04 12 13012130SteelZinc plated40
Tecfi AJ 04 12 16012160SteelZinc plated70
Tecfi AJ 04 16 0901690——5
Tecfi AJ 04 16 12516125SteelZinc plated5
Tecfi AJ 04 16 14516145SteelZinc plated25
Tecfi AJ 04 16 18016180SteelZinc plated60
Tecfi AJ 04 24 16024160SteelZinc plated10
Tecfi AJ 04 24 20024200SteelZinc plated30
Tecfi AJ 04 24 26024260SteelZinc plated90
Tecfi AJ 04 24 31024310SteelZinc plated140

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi AJ02 · Through-bolt expansion anchorsAJ02Tecfi · 10 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
Tecfi AJ02 · Through-bolt expansion anchors
Series reference image · Tecfi

Series characteristics AJ02

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Stainless A2.

Documented series dimensions: nominal Ø 6–12 mm; length 60–180 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi AJ02 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfix
Tecfi AJ 02 06 1006100Acciaio / Acciaio Inox A2Zinc plated50
Tecfi AJ 02 08 060860Acciaio / Acciaio Inox A2Zinc plated5
Tecfi AJ 02 08 080880Acciaio / Acciaio Inox A2Zinc plated25
Tecfi AJ 02 08 1158115Acciaio / Acciaio Inox A2Zinc plated60
Tecfi AJ 02 08 1358135Acciaio / Acciaio Inox A2Zinc plated80
Tecfi AJ 02 10 0701070Acciaio / Acciaio Inox A2Zinc plated5
Tecfi AJ 02 10 14010140Acciaio / Acciaio Inox A2Zinc plated75
Tecfi AJ 02 12 10012100Acciaio / Acciaio Inox A2Zinc plated20
Tecfi AJ 02 12 14012140Acciaio / Acciaio Inox A2Zinc plated60
Tecfi AJ 02 12 18012180Acciaio / Acciaio Inox A2Zinc plated100

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT BA-E Plus HCR · Through-bolt expansion anchorsBA-E Plus HCREJOT · 6 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
EJOT BA-E Plus HCR · Through-bolt expansion anchors
Series reference image · EJOT

Series characteristics BA-E Plus HCR

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: HCR stainless.

Documented series dimensions: length 45–112 mm; thread Ø 8–10 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT BA-E Plus HCR · dimensional and installation characteristics
Part number and sourceLength (mm)Thread Ø (mm)Fixture thickness B ≥ (mm)Hole depth (mm), as stated by the sourceAnchorage depth (mm)HEX
EJOT 965000630857.08.05473513.0
EJOT 965000631075.08.023.047/6035/4813.0
EJOT 965000631245.08.043/3047/6035/8013.0
EJOT 965000632372.010.010.0554017.0
EJOT 965000632592.010.030/1055/7540/6017.0
EJOT 9650006327112.010.050.055/7540/6017.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT BA-V Plus · Through-bolt expansion anchorsBA-V PlusEJOT · 21 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
EJOT BA-V Plus · Through-bolt expansion anchors
Series reference image · EJOT

Series characteristics BA-V Plus

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: length 72–178 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT BA-V Plus · dimensional and installation characteristics
Part number and sourceLength (mm)Thread Ø (mm)Fixture thickness B ≥ (mm)Hole depth (mm), as stated by the sourceAnchorage depth (mm)Wrench size (mm)Effective anchorage depth h ef ≥ mm
EJOT 965000131075.08.023/1047/6035/4813.035.0
EJOT 965000131295.08.043/3047/6035/4813.035.0
EJOT 9650001314115.08.063.047——35.0
EJOT 9650001316150.08.098.047——35.0
EJOT 965000132372.010.010.0554017.040.0
EJOT 965000132592.010.010.055/7540/6017.040.0
EJOT 9650001326102.010.040.055/7540/6017.0—
EJOT 9650001327112.010.050.0———40.0
EJOT 9650001329132.010.070.0———40.0
EJOT 9650001331162.010.0100.0———40.0
EJOT 965000133888.012.010.0705019.050.0
EJOT 9650001340103.012.025.070/9050/7019.050.0
EJOT 9650001342118.012.040.070/9050/7019.050.0
EJOT 9650001343128.012.050.0———50.0
EJOT 9650001345148.012.070.0———50.0
EJOT 9650001346163.012.085.0———50.0
EJOT 9650001347178.012.0100.0———50.0
EJOT 9650001357123.016.05.0———85.0
EJOT 9650001359138.016.020.01108524.085.0
EJOT 9650001362168.016.050.01108524.085.0
EJOT 9650001363178.016.060.0———85.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT BA-F Plus · Through-bolt expansion anchorsBA-F PlusEJOT · 21 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
EJOT BA-F Plus · Through-bolt expansion anchors
Series reference image · EJOT

Series characteristics BA-F Plus

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: length 72–178 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT BA-F Plus · dimensional and installation characteristics
Part number and sourceThread Ø (mm)Length (mm)Hole depth ≤ (mm), source wordingFixture thickness B ≥ (mm)Effective anchorage depth h ef ≥ mm
EJOT 96500033108.075.047.023.035.0
EJOT 96500033128.095.047.043.035.0
EJOT 96500033148.0115.047.063.035.0
EJOT 96500033168.0150.047.098.035.0
EJOT 965000332310.072.055.010.040.0
EJOT 965000332510.092.055.030.040.0
EJOT 965000332610.0102.055.040.040.0
EJOT 965000332710.0112.055.050.040.0
EJOT 965000332910.0132.055.070.040.0
EJOT 965000333110.0162.055.0100.040.0
EJOT 965000333812.088.070.010.050.0
EJOT 965000334012.0103.070.025.050.0
EJOT 965000334212.0118.070.040.050.0
EJOT 965000334312.0128.070.050.050.0
EJOT 965000334512.0148.070.070.050.0
EJOT 965000334612.0163.070.085.050.0
EJOT 965000334712.0178.070.0100.050.0
EJOT 965000335716.0123.0110.05.085.0
EJOT 965000335916.0138.0110.020.085.0
EJOT 965000336216.0168.0110.050.085.0
EJOT 965000336316.0178.0110.060.085.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT BA-E Plus · Through-bolt expansion anchorsBA-E PlusEJOT · 21 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
EJOT BA-E Plus · Through-bolt expansion anchors
Series reference image · EJOT

Series characteristics BA-E Plus

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Stainless A4, HCR stainless.

Documented series dimensions: length 72–178 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT BA-E Plus · dimensional and installation characteristics
Part number and sourceLength (mm)Thread Ø (mm)Hole depth (mm), as stated by the sourceAnchorage depth (mm)Wrench size (mm)Hole depth ≤ (mm), source wordingFixture thickness B ≥ (mm)Effective anchorage depth h ef ≥ mm
EJOT 965000531075.08.047/6035/4813.047.023.035.0
EJOT 965000531295.08.047/6035/4813.047.043.035.0
EJOT 9650005314115.08.0———47.063.035.0
EJOT 9650005316150.08.0———47.098.035.0
EJOT 965000532372.010.0354017.055.010.040.0
EJOT 965000532592.010.055/7540/6017.055.030.040.0
EJOT 9650005326102.010.055/7540/6017.055.040.040.0
EJOT 9650005327112.010.0———55.050.040.0
EJOT 9650005329132.010.0———55.070.040.0
EJOT 9650005331162.010.0———55.0100.040.0
EJOT 965000533888.012.0705019.070.010.050.0
EJOT 9650005340103.012.070/9050/7019.070.025.050.0
EJOT 9650005342118.012.070/9050/7019.070.040.050.0
EJOT 9650005343128.012.0———70.050.050.0
EJOT 9650005345148.012.0———70.070.050.0
EJOT 9650005346163.012.0———70.085.050.0
EJOT 9650005347178.012.0———70.0100.050.0
EJOT 9650005357123.016.0———110.05.085.0
EJOT 9650005359138.016.01108524.0110.020.085.0
EJOT 9650005362168.016.01108524.0110.050.085.0
EJOT 9650005363178.016.0———110.060.085.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT BA-C NC · Through-bolt expansion anchorsBA-C NCEJOT · 14 referencesThrough-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.Full description and technical table ↓
EJOT BA-C NC · Through-bolt expansion anchors
Series reference image · EJOT

Series characteristics BA-C NC

Through-bolt anchor with tightening-activated expansion. Inserted depth and fixture thickness must match the selected configuration.

Materials represented by the variants: Steel.

Documented series dimensions: length 75–175 mm; thread Ø 8–16 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Check drill diameter, depth, fixture thickness and installation torque. Cracked concrete, seismic action and fire are specific documented scopes, not implicit properties of every through-bolt.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT BA-C NC · dimensional and installation characteristics
Part number and sourceLength (mm)Thread Ø (mm)Hole depth ≤ (mm), source wordingDrill bit Ø (mm)Fixture thickness B ≥ (mm)Effective anchorage depth h ef ≥ mm
EJOT 965000720275.08.063.08.010.043.0
EJOT 965000720395.08.063.08.030.043.0
EJOT 9650007205115.08.063.08.050.043.0
EJOT 965000720885.010.069.010.010.050.0
EJOT 965000720995.010.069.010.020.050.0
EJOT 9650007210105.010.069.010.030.050.0
EJOT 9650007211125.010.069.010.050.050.0
EJOT 9650007212110.012.092.012.010.070.0
EJOT 9650007213120.012.092.012.020.070.0
EJOT 9650007214130.012.092.012.030.070.0
EJOT 9650007215150.012.092.012.050.070.0
EJOT 9650007217135.016.0109.016.010.085.0
EJOT 9650007219145.016.0109.016.020.085.0
EJOT 9650007220175.016.0109.016.050.085.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Anchor finder

Search by part number or select declared characteristics. Missing data do not satisfy a dimensional filter.

Request technical review or a quotation

Select a finder reference or describe the application.

The summary is transferred to the contact form for your review and submission.

FAQ

How do I select an anchor?

Start with substrate, load and environment, then identify configuration, depth, distances and part-specific documentation. The finder selects catalogue references and does not perform a design check.

Does equal diameter mean equal capacity?

No. Geometry, material, anchorage and technical assessment may differ. Dimensional comparison does not establish technical equivalence or interchangeability.

Do all anchors have an ETA and CE marking?

These cannot be assigned to an entire category. Check the product documentation, scope and applicability to the specific size. An ETA link does not extend its assessment to other parts.

What information is needed for an enquiry?

Part number or family, quantity, substrate material and condition, thicknesses, fixing geometry, environment, actions and required documents. For resins, also specify temperature and hole conditions.

Sources and documentation

Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.

Tecfi · EJOT

Dueemme Sidol S.r.l. · Sesto San Giovanni, Milan · Supply for industrial customers and OEMs.

Dueemme Sidol
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.