Industrial fixings · Dueemme Sidol

Heavy-duty and undercut anchors

Heavy-duty and undercut families use specific load-transfer mechanisms. The commercial designation does not assign a common load capacity to the family.

Tecfi HVE01 · Heavy-duty and undercut anchors
Family example · Tecfi HVE01

Features and selection criteria

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.

Designs, materials and substrates

This family contains 11 series or reference groups, with 115 catalogue rows. Series photographs help distinguish geometries and fixing methods; they do not necessarily represent every size in the range.

Documented materials

Steel · Stainless A4

Substrates mentioned in the sources

Concrete · Cracked concrete

This list describes the family and does not assign every substrate to every variant.

Information to define before selection

ParameterWhat to check
Load-bearing substrateMaterial type, strength, any cracking, useful thickness and hole conditions. Compatibility must be established for the selected design and size.
Fixing geometryTotal length, body or thread diameter and drill diameter are distinct parameters. Through-fixings must allow for fixture thickness and non-load-bearing layers.
Depth and distancesCompare hole depth, nominal or effective anchorage depth, edge distances and spacing. A deeper hole does not automatically increase fixing capacity.
Environment and exposureCheck material and coating of all components, temperature and service conditions. A2, A4 and HCR stainless designs require selection appropriate to the environment.
Loads and documentationDefine action directions and combinations and check the part-specific document. Dimensional data identify the part but do not replace a design verification.

Installation sequence to verify

  1. Identify the exact system configuration in the ETA and design.
  2. Drill and form any undercut using the specified equipment.
  3. Check depth, cleaning and correct mechanism activation.
  4. Check tightening and the manufacturer’s verification criteria.

This sequence guides the reading of the instructions. Diameters, depths, equipment and tightening values remain those of the specific variant.

Series and technical tables

Tecfi HVE01 · Heavy-duty and undercut anchorsHVE01Tecfi · 20 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: hexagonal head.Full description and technical table ↓
Tecfi HVE01 · Heavy-duty and undercut anchors
Series reference image · Tecfi

Series characteristics HVE01

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: hexagonal head.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 10–24 mm; length 70–220 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi HVE01 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfixMisura vite MPart-specific documentation indicators
Tecfi HVE 01 10 0701070SteelZinc plated5M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 10 0801080SteelZinc plated15M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 10 10010100SteelZinc plated35M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 10 12010120SteelZinc plated55M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 12 0801280SteelZinc plated10M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 12 10012100SteelZinc plated30M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 12 12012120SteelZinc plated50M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 12 14012140SteelZinc plated70M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 16 10016100SteelZinc plated20M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 16 12016120SteelZinc plated40M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 16 14016140SteelZinc plated60M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 16 16016160SteelZinc plated80M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 18 12018120SteelZinc plated20M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 18 15018150SteelZinc plated50M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 18 17018170SteelZinc plated70M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 18 20018200SteelZinc plated100M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 24 14024140SteelZinc plated20M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 24 17024170SteelZinc plated50M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 24 20024200SteelZinc plated80M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 01 24 22024220SteelZinc plated100M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi HVE02 · Heavy-duty and undercut anchorsHVE02Tecfi · 20 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.Full description and technical table ↓
Tecfi HVE02 · Heavy-duty and undercut anchors
Series reference image · Tecfi

Series characteristics HVE02

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 10–24 mm; length 70–220 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi HVE02 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfixMisura vite MPart-specific documentation indicators
Tecfi HVE 02 10 0701070SteelZinc plated5M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 10 0801080SteelZinc plated15M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 10 10010100SteelZinc plated35M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 10 12010120SteelZinc plated55M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 12 0801280SteelZinc plated10M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 12 10012100SteelZinc plated30M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 12 12012120SteelZinc plated50M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 12 14012140SteelZinc plated70M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 16 10016100SteelZinc plated20M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 16 12016120SteelZinc plated40M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 16 14016140SteelZinc plated60M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 16 16016160SteelZinc plated80M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 18 12018120SteelZinc plated20M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 18 15018150SteelZinc plated50M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 18 17018170SteelZinc plated70M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 18 20018200SteelZinc plated100M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 24 14024140SteelZinc plated20M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 24 17024170SteelZinc plated50M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 24 20024200SteelZinc plated80M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 02 24 22024220SteelZinc plated100M16ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi HVE03 · Heavy-duty and undercut anchorsHVE03Tecfi · 10 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: countersunk head.Full description and technical table ↓
Tecfi HVE03 · Heavy-duty and undercut anchors
Series reference image · Tecfi

Series characteristics HVE03

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: countersunk head.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 10–18 mm; length 85–140 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi HVE03 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfixMisura vite MPart-specific documentation indicators
Tecfi HVE 03 10 0851085SteelZinc plated20M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 10 10510105SteelZinc plated40M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 10 12510125SteelZinc plated60M6ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 12 0851285SteelZinc plated15M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 12 10512105SteelZinc plated35M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 12 12512125SteelZinc plated55M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 16 11016110SteelZinc plated30M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 16 13016130SteelZinc plated50M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 18 12018120SteelZinc plated20M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 03 18 14018140SteelZinc plated40M12ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Tecfi HVE04 · Heavy-duty and undercut anchorsHVE04Tecfi · 5 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: six-lobe drive.Full description and technical table ↓
Tecfi HVE04 · Heavy-duty and undercut anchors
Series reference image · Tecfi

Series characteristics HVE04

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: six-lobe drive.

Materials represented by the variants: Steel.

Documented series dimensions: nominal Ø 12–16 mm; length 80–120 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

Tecfi HVE04 · dimensional and installation characteristics
Part number and sourceNominal Ø dnom (mm)Length L (mm)MaterialFinishFixture thickness (mm) tfixMisura vite MPart-specific documentation indicators
Tecfi HVE 04 12 0801280SteelZinc plated10M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 04 12 10012100SteelZinc plated30M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 04 12 12012120SteelZinc plated50M8ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 04 16 10016100SteelZinc plated20M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic
Tecfi HVE 04 16 12016120SteelZinc plated40M10ETA-CE · EAD 330232-00-0601 · R049
R120 (TR 020)
R049 · Sisma / Seismic

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT Tassello di sicurezza LIEBIG® SK · Heavy-duty and undercut anchorsTassello di sicurezza LIEBIG® SKEJOT · 10 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.Full description and technical table ↓
EJOT Tassello di sicurezza LIEBIG® SK · Heavy-duty and undercut anchors
Series reference image · EJOT

Series characteristics Tassello di sicurezza LIEBIG® SK

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.

Materials represented by the variants: Steel.

Documented series dimensions: length 70–160 mm; thread Ø 10–25 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT Tassello di sicurezza LIEBIG® SK · dimensional and installation characteristics
Part number and sourceNominal sizeLength (mm)Thread Ø (mm)Hole depth ≤ (mm), source wordingDrill bit Ø (mm)Fixture thickness B ≥ (mm)Fixture thickness (mm)ø cone d k ≥Height cone kHEX
EJOT 9650045415M670.010.060.010.015.015.020.05.550.0
EJOT 9650045440M695.010.060.0—40.0—20.05.550.0
EJOT 9652055415M885.012.070.012.015.015.020.06.525.0
EJOT 9652055440M8110.012.070.012.040.040.024.06.525.0
EJOT 9655070415—100.015.085.015.015.015.0———
EJOT 9655070440—120.015.085.015.040.040.0———
EJOT 9650080415—110.020.0100.020.015.015.0———
EJOT 9650080440—135.020.0100.020.040.040.0———
EJOT 9655100415—135.025.0125.025.015.015.0———
EJOT 9655100440—160.025.0125.025.040.040.0———

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT Tassello di sicurezza LIEBIG® S · Heavy-duty and undercut anchorsTassello di sicurezza LIEBIG® SEJOT · 15 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.Full description and technical table ↓
EJOT Tassello di sicurezza LIEBIG® S · Heavy-duty and undercut anchors
Series reference image · EJOT

Series characteristics Tassello di sicurezza LIEBIG® S

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.

Materials represented by the variants: Steel.

Documented series dimensions: length 70–180 mm; thread Ø 10–25 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT Tassello di sicurezza LIEBIG® S · dimensional and installation characteristics
Part number and sourceLength (mm)Thread Ø (mm)Hole depth ≤ (mm), source wordingDrill bit Ø (mm)Fixture thickness B ≥ (mm)Fixture thickness (mm)
EJOT 965004510570.010.060.010.05.05.0
EJOT 965004511580.010.060.010.015.015.0
EJOT 9650045140105.010.060.0—40.0—
EJOT 965205510580.012.070.0—5.0—
EJOT 965205511590.012.070.012.015.015.0
EJOT 9652055140115.012.070.012.040.040.0
EJOT 965507010595.015.085.0—5.0—
EJOT 9655070115105.015.085.015.015.015.0
EJOT 9655070140130.015.085.015.040.040.0
EJOT 9650080105113.020.0100.0—5.0—
EJOT 9650080115123.020.0100.020.015.015.0
EJOT 9650080140148.020.0100.020.040.040.0
EJOT 9655100105145.025.0125.0—5.0—
EJOT 9655100115155.025.0125.025.015.015.0
EJOT 9655100140180.025.0125.025.040.040.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT Tassello di sicurezza LIEBIG® B · Heavy-duty and undercut anchorsTassello di sicurezza LIEBIG® BEJOT · 23 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.Full description and technical table ↓
EJOT Tassello di sicurezza LIEBIG® B · Heavy-duty and undercut anchors
Series reference image · EJOT

Series characteristics Tassello di sicurezza LIEBIG® B

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.

Materials represented by the variants: Steel.

Documented series dimensions: length 70–245 mm; thread Ø 10–25 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT Tassello di sicurezza LIEBIG® B · dimensional and installation characteristics
Part number and sourceLength (mm)Thread Ø (mm)Hole depth ≤ (mm), source wordingDrill bit Ø (mm)Fixture thickness B ≥ (mm)Fixture thickness (mm)
EJOT 965004500570.010.060.010.05.05.0
EJOT 965004501580.010.060.010.015.015.0
EJOT 9650045040105.010.060.0—40.0—
EJOT 965205500585.012.070.0—5.0—
EJOT 965205501595.012.070.012.015.015.0
EJOT 9652055040120.012.070.012.040.040.0
EJOT 9652055065145.012.075.0—65.0—
EJOT 9652055100180.012.070.0—100.0—
EJOT 9655070005100.015.085.0—5.0—
EJOT 9655070015110.015.085.015.015.015.0
EJOT 9655070040135.015.085.015.040.040.0
EJOT 9655070065160.015.085.0—65.0—
EJOT 9655070100195.015.085.0—100.0—
EJOT 9650080005120.020.0100.0—5.0—
EJOT 9650080040155.020.0100.020.040.040.0
EJOT 9650080065180.020.0100.0—65.0—
EJOT 9650080100215.020.0100.0—100.0—
EJOT 9650280015130.020.0100.020.015.015.0
EJOT 9655100005150.025.0125.0—5.0—
EJOT 9655100015160.025.0125.025.015.015.0
EJOT 9655100040185.025.0125.025.040.040.0
EJOT 9655100065210.025.0125.0—65.0—
EJOT 9655100100245.025.0125.0—100.0—

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT LIEBIG® SUPERPLUS ILS · Heavy-duty and undercut anchorsLIEBIG® SUPERPLUS ILSEJOT · 1 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.Full description and technical table ↓
EJOT LIEBIG® SUPERPLUS ILS · Heavy-duty and undercut anchors
Series reference image · EJOT

Series characteristics LIEBIG® SUPERPLUS ILS

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.

Materials represented by the variants: Steel.

Documented series dimensions: length 95 mm; thread Ø 14 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT LIEBIG® SUPERPLUS ILS · dimensional and installation characteristics
Part number and sourceMaterialLength (mm)Thread Ø (mm)Hole depth ≤ (mm), source wording
EJOT 9650814080Acciaio al carbonio95.014.0100.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT LIEBIG® SUPERPLUS BLS A4 · Heavy-duty and undercut anchorsLIEBIG® SUPERPLUS BLS A4EJOT · 3 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: undercut anchorage.Full description and technical table ↓
EJOT LIEBIG® SUPERPLUS BLS A4 · Heavy-duty and undercut anchors
Series reference image · EJOT

Series characteristics LIEBIG® SUPERPLUS BLS A4

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: undercut anchorage.

Materials represented by the variants: Stainless A4.

Documented series dimensions: length 130–220 mm; thread Ø 14–25 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT LIEBIG® SUPERPLUS BLS A4 · dimensional and installation characteristics
Part number and sourceNominal sizeLength (mm)Thread Ø (mm)Hole depth ≤ (mm), source wordingFixture thickness B ≥ (mm)Fixture thickness (mm)
EJOT 9654080254M8130.014.0100.025.025.0
EJOT 9650080154M12130.020.0105.015.015.0
EJOT 9655150304M16220.025.0185.030.030.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT LIEBIG® SUPERPLUS BLS M8-14 A4 · Heavy-duty and undercut anchorsLIEBIG® SUPERPLUS BLS M8-14 A4EJOT · 1 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.Full description and technical table ↓
EJOT LIEBIG® SUPERPLUS BLS M8-14 A4 · Heavy-duty and undercut anchors
Series reference image · EJOT

Series characteristics LIEBIG® SUPERPLUS BLS M8-14 A4

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document.

Materials represented by the variants: Stainless A4.

Substrates mentioned in the series sources: Concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT LIEBIG® SUPERPLUS BLS M8-14 A4 · dimensional and installation characteristics
Part number and source
EJOT 9650814085

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

EJOT LIEBIG® SUPERPLUS BLS · Heavy-duty and undercut anchorsLIEBIG® SUPERPLUS BLSEJOT · 7 referencesAnchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: undercut anchorage.Full description and technical table ↓
EJOT LIEBIG® SUPERPLUS BLS · Heavy-duty and undercut anchors
Series reference image · EJOT

Series characteristics LIEBIG® SUPERPLUS BLS

Anchoring system for applications requiring specific assessment of load transfer. Expansion or undercut geometry and installation configuration must be identified in the product document. Series design: undercut anchorage.

Materials represented by the variants: Steel.

Documented series dimensions: length 130–300 mm; thread Ø 14–25 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.

Substrates mentioned in the series sources: Concrete, Cracked concrete. Check the application scope for the individual part.

Part identification, ETA and installation configuration are required. Check member thickness, edges, spacing, reinforcement, combined loads and manufacturer-specified setting equipment.

The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.

View the manufacturer’s product page ↗

Part-specific technical table

Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.

EJOT LIEBIG® SUPERPLUS BLS · dimensional and installation characteristics
Part number and sourceNominal sizeLength (mm)Thread Ø (mm)Hole depth ≤ (mm), source wordingDrill bit Ø (mm)Fixture thickness B ≥ (mm)Fixture thickness (mm)
EJOT 9654080025M8130.014.0100.08.025.025.0
EJOT 9650080015M12130.020.0105.012.015.015.0
EJOT 9650080030M12145.020.0105.012.030.030.0
EJOT 9655150030M16220.025.0185.016.030.030.0
EJOT 9655150404M16230.025.0185.0—40.040.0
EJOT 9655200040M16280.025.0235.016.040.040.0
EJOT 9655200060M16300.025.0235.016.060.060.0

ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.

Anchor finder

Search by part number or select declared characteristics. Missing data do not satisfy a dimensional filter.

Request technical review or a quotation

Select a finder reference or describe the application.

The summary is transferred to the contact form for your review and submission.

FAQ

How do I select an anchor?

Start with substrate, load and environment, then identify configuration, depth, distances and part-specific documentation. The finder selects catalogue references and does not perform a design check.

Does equal diameter mean equal capacity?

No. Geometry, material, anchorage and technical assessment may differ. Dimensional comparison does not establish technical equivalence or interchangeability.

Do all anchors have an ETA and CE marking?

These cannot be assigned to an entire category. Check the product documentation, scope and applicability to the specific size. An ETA link does not extend its assessment to other parts.

What information is needed for an enquiry?

Part number or family, quantity, substrate material and condition, thicknesses, fixing geometry, environment, actions and required documents. For resins, also specify temperature and hole conditions.

Sources and documentation

Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.

Tecfi · EJOT

Dueemme Sidol S.r.l. · Sesto San Giovanni, Milan · Supply for industrial customers and OEMs.

Dueemme Sidol
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.