Insulation and ETICS anchors
ETICS anchors pass through the insulation into the load-bearing substrate. Plate, expansion element and installation method form part of the system configuration.

Features and selection criteria
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Designs, materials and substrates
This family contains 12 series or reference groups, with 102 catalogue rows. Series photographs help distinguish geometries and fixing methods; they do not necessarily represent every size in the range.
Documented materials
Other polymers · Nylon · Steel
Substrates mentioned in the sources
Concrete · Masonry · Aerated concrete · Insulation · Perforated masonry
This list describes the family and does not assign every substrate to every variant.
Information to define before selection
| Parameter | What to check |
|---|---|
| Load-bearing substrate | Material type, strength, any cracking, useful thickness and hole conditions. Compatibility must be established for the selected design and size. |
| Fixing geometry | Total length, body or thread diameter and drill diameter are distinct parameters. Through-fixings must allow for fixture thickness and non-load-bearing layers. |
| Depth and distances | Compare hole depth, nominal or effective anchorage depth, edge distances and spacing. A deeper hole does not automatically increase fixing capacity. |
| Environment and exposure | Check material and coating of all components, temperature and service conditions. A2, A4 and HCR stainless designs require selection appropriate to the environment. |
| Loads and documentation | Define action directions and combinations and check the part-specific document. Dimensional data identify the part but do not replace a design verification. |
Installation sequence to verify
- Identify substrate category, insulation and assembly thickness.
- Select length and anchorage depth allowing for non-load-bearing layers.
- Use flush or recessed installation only where permitted by the design and system.
- Check plate bearing, fixing layout and specified surface treatment.
This sequence guides the reading of the instructions. Diameters, depths, equipment and tightening values remain those of the specific variant.
Series and technical tables
BN01Tecfi · 5 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics BN01
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Materials represented by the variants: Other polymers.
Documented series dimensions: nominal Ø 8 mm; length 50–130 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Anchor body Ø (mm) | Anchor length (mm) | Material | Drill Ø d₀ (mm) | Tfix (spess. fissabile) MIN | Tfix (spess. fissabile) MAX |
|---|---|---|---|---|---|---|
| Tecfi BN 01 08 050 | 8 | 50 | Polypropylene | 8 | 10 | 20 - |
| Tecfi BN 01 08 070 | 8 | 70 | Polypropylene | 8 | 20 | 40 - |
| Tecfi BN 01 08 085 | 8 | 85 | Polypropylene | 8 | 40 | 60 - |
| Tecfi BN 01 08 110 | 8 | 110 | Polypropylene | 8 | 60 | 80 - |
| Tecfi BN 01 08 130 | 8 | 130 | Polypropylene | 8 | 80 | 100 - |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ZZE01Tecfi · 8 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.Full description and technical table ↓

Series characteristics ZZE01
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.
Materials represented by the variants: Nylon, Other polymers.
Documented series dimensions: nominal Ø 10 mm; length 70–240 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Anchor body Ø (mm) | Anchor length (mm) | Material | Fixture thickness max (mm) | Part-specific documentation indicators |
|---|---|---|---|---|---|
| Tecfi ZZE 01 10 070 | 10 | 70 | HDPE / Nylon | 30 | ETA-CE |
| Tecfi ZZE 01 10 090 | 10 | 90 | HDPE / Nylon | 50 | ETA-CE |
| Tecfi ZZE 01 10 110 | 10 | 110 | HDPE / Nylon | 70 | ETA-CE |
| Tecfi ZZE 01 10 130 | 10 | 130 | HDPE / Nylon | 90 | ETA-CE |
| Tecfi ZZE 01 10 150 | 10 | 150 | HDPE / Nylon | 110 | ETA-CE |
| Tecfi ZZE 01 10 180 | 10 | 180 | HDPE / Nylon | 140 | ETA-CE |
| Tecfi ZZE 01 10 210 | 10 | 210 | HDPE / Nylon | 170 | ETA-CE |
| Tecfi ZZE 01 10 240 | 10 | 240 | HDPE / Nylon | 200 | ETA-CE |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ZZE21Tecfi · 8 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.Full description and technical table ↓

Series characteristics ZZE21
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.
Materials represented by the variants: Other polymers, Steel.
Documented series dimensions: nominal Ø 10 mm; length 70–240 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Anchor body Ø (mm) | Anchor length (mm) | Material | Finish | Fixture thickness max (mm) | Part-specific documentation indicators |
|---|---|---|---|---|---|---|
| Tecfi ZZE 21 10 070 | 10 | 70 | HDPE / Acciaio | Zinc plated | 30 | ETA-CE |
| Tecfi ZZE 21 10 090 | 10 | 90 | HDPE / Acciaio | Zinc plated | 50 | ETA-CE |
| Tecfi ZZE 21 10 110 | 10 | 110 | HDPE / Acciaio | Zinc plated | 70 | ETA-CE |
| Tecfi ZZE 21 10 130 | 10 | 130 | HDPE / Acciaio | Zinc plated | 90 | ETA-CE |
| Tecfi ZZE 21 10 150 | 10 | 150 | HDPE / Acciaio | Zinc plated | 110 | ETA-CE |
| Tecfi ZZE 21 10 180 | 10 | 180 | HDPE / Acciaio | Zinc plated | 140 | ETA-CE |
| Tecfi ZZE 21 10 210 | 10 | 210 | HDPE / Acciaio | Zinc plated | 170 | ETA-CE |
| Tecfi ZZE 21 10 240 | 10 | 240 | HDPE / Acciaio | Zinc plated | 200 | ETA-CE |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ZZER01Tecfi · 1 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics ZZER01
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Materials represented by the variants: Other polymers.
Documented series dimensions: nominal Ø 90 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Disc Ø (mm) | Material | Part-specific documentation indicators |
|---|---|---|---|
| Tecfi ZZER 01 10 090 | 90 | HDPE | ETA-CE |
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ejotherm® H2EJOT · 11 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.Full description and technical table ↓

Series characteristics ejotherm® H2
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.
Materials represented by the variants: Other polymers, Steel.
Documented series dimensions: nominal Ø 8 mm; length 95–295 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Masonry, Aerated concrete, Insulation. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Plate/washer Ø (mm) | Anchor Ø (mm) | Length (mm) |
|---|---|---|---|
| EJOT 8528095260 | 60.0 | 8.0 | 95.0 |
| EJOT 8528115260 | 60.0 | 8.0 | 115.0 |
| EJOT 8528135260 | 60.0 | 8.0 | 135.0 |
| EJOT 8528155260 | 60.0 | 8.0 | 155.0 |
| EJOT 8528175260 | 60.0 | 8.0 | 175.0 |
| EJOT 8528195260 | 60.0 | 8.0 | 195.0 |
| EJOT 8528215260 | 60.0 | 8.0 | 215.0 |
| EJOT 8528235260 | 60.0 | 8.0 | 235.0 |
| EJOT 8528255260 | 60.0 | 8.0 | 255.0 |
| EJOT 8528275260 | 60.0 | 8.0 | 275.0 |
| EJOT 8528295260 | 60.0 | 8.0 | 295.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ejotherm® H1EJOT · 14 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.Full description and technical table ↓

Series characteristics ejotherm® H1
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration. Series design: nail activation.
Materials represented by the variants: Other polymers, Steel.
Documented series dimensions: nominal Ø 8 mm; length 95–355 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Masonry, Aerated concrete, Insulation. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Plate/washer Ø (mm) | Anchor Ø (mm) | Length (mm) |
|---|---|---|---|
| EJOT 8744095400 | 60.0 | 8.0 | 95.0 |
| EJOT 8744115400 | 60.0 | 8.0 | 115.0 |
| EJOT 8744135400 | 60.0 | 8.0 | 135.0 |
| EJOT 8744155400 | 60.0 | 8.0 | 155.0 |
| EJOT 8744175400 | 60.0 | 8.0 | 175.0 |
| EJOT 8744195400 | 60.0 | 8.0 | 195.0 |
| EJOT 8744215400 | 60.0 | 8.0 | 215.0 |
| EJOT 8744235400 | 60.0 | 8.0 | 235.0 |
| EJOT 8744255400 | 60.0 | 8.0 | 255.0 |
| EJOT 8744275400 | 60.0 | 8.0 | 275.0 |
| EJOT 8744295400 | 60.0 | 8.0 | 295.0 |
| EJOT 8744315400 | 60.0 | 8.0 | 315.0 |
| EJOT 8744335400 | 60.0 | 8.0 | 335.0 |
| EJOT 8744355400 | 60.0 | 8.0 | 355.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ejotherm® S1 shortEJOT · 3 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics ejotherm® S1 short
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Documented series dimensions: length 60–100 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Insulation. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Length (mm) |
|---|---|
| EJOT 8715060570 | 60.0 |
| EJOT 8715080570 | 80.0 |
| EJOT 8715100570 | 100.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
H3EJOT · 9 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics H3
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Materials represented by the variants: Nylon.
Documented series dimensions: nominal Ø 8 mm; length 75–235 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Masonry, Perforated masonry. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Plate/washer Ø (mm) | Anchor Ø (mm) | Length (mm) | Activation method |
|---|---|---|---|---|
| EJOT 8573075100 | 60.0 | 8.0 | 75.0 | Fissaggio a percussione |
| EJOT 8573095100 | 60.0 | 8.0 | 95.0 | Fissaggio a percussione |
| EJOT 8573115100 | 60.0 | 8.0 | 115.0 | Fissaggio a percussione |
| EJOT 8573135100 | 60.0 | 8.0 | 135.0 | Fissaggio a percussione |
| EJOT 8573155100 | 60.0 | 8.0 | 155.0 | Fissaggio a percussione |
| EJOT 8573175100 | 60.0 | 8.0 | 175.0 | Fissaggio a percussione |
| EJOT 8573195100 | 60.0 | 8.0 | 195.0 | Fissaggio a percussione |
| EJOT 8573215100 | 60.0 | 8.0 | 215.0 | Fissaggio a percussione |
| EJOT 8573235100 | 60.0 | 8.0 | 235.0 | Fissaggio a percussione |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ejotherm® STR U 2GEJOT · 17 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics ejotherm® STR U 2G
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 8 mm; length 115–455 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Masonry, Aerated concrete, Insulation. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Plate/washer Ø (mm) | Anchor Ø (mm) | Length (mm) | Fissaggio | Tolleranza | Activation method | Material |
|---|---|---|---|---|---|---|---|
| EJOT 8719115400 | 60.0 | 8.0 | 115.0 | Montaggio a filo e ad incasso | 3.0 | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719135400 | 60.0 | 8.0 | 135.0 | Montaggio a filo e ad incasso solo montaggio a filo | 10.0 30.0 50.0 | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719155400 | 60.0 | 8.0 | 155.0 | Montaggio a filo e ad incasso solo montaggio a filo | 10.0 30.0 50.0 70.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719175400 | 60.0 | 8.0 | 175.0 | Montaggio a filo e ad incasso solo montaggio a filo | 10.0 30.0 70.0 | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719195400 | 60.0 | 8.0 | 195.0 | solo montaggio a filo Montaggio a filo e ad incasso | 10.0 30.0 50.0 70.0 90.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719215400 | 60.0 | 8.0 | 215.0 | solo montaggio a filo Montaggio a filo e ad incasso | 10.0 30.0 50.0 70.0 90.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719235400 | 60.0 | 8.0 | 235.0 | Montaggio a filo e ad incasso | 10.0 30.0 50.0 70.0 90.0 110.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719255400 | 60.0 | 8.0 | 255.0 | Montaggio a filo e ad incasso | 10.0 30.0 50.0 70.0 90.0 110.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719275400 | 60.0 | 8.0 | 275.0 | solo montaggio a filo Montaggio a filo e ad incasso | 90.0 110.0 70.0 50.0 30.0 10.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719295400 | 60.0 | 8.0 | 295.0 | solo montaggio a filo Montaggio a filo e ad incasso | 10.0 30.0 50.0 70.0 90.0 110.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719315400 | 60.0 | 8.0 | 315.0 | solo montaggio a filo Montaggio a filo e ad incasso | 10.0 30.0 50.0 70.0 90.0 110.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719355400 | 60.0 | 8.0 | 355.0 | Montaggio a filo e ad incasso | 10.0 30.0 50.0 70.0 90.0 110.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719375400 | 60.0 | 8.0 | 375.0 | Montaggio a filo e ad incasso | 90.0 110.0 70.0 50.0 30.0 10.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719395400 | 60.0 | 8.0 | 395.0 | Montaggio a filo e ad incasso | 50.0 110.0 90.0 70.0 10.0 30.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719415400 | 60.0 | 8.0 | 415.0 | Montaggio a filo e ad incasso | 110.0 10.0 70.0 90.0 50.0 30.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719435400 | 60.0 | 8.0 | 435.0 | Montaggio a filo e ad incasso | 30.0 90.0 50.0 70.0 10.0 110.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
| EJOT 8719455400 | 60.0 | 8.0 | 455.0 | Montaggio a filo e ad incasso | 50.0 70.0 90.0 10.0 30.0 110.0 show more | Fissaggio ad avvitamento | Acciaio al carbonio |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ejotherm® S1EJOT · 19 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics ejotherm® S1
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Documented series dimensions: length 100–460 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Masonry, Perforated masonry, Aerated concrete, Insulation. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Length (mm) |
|---|---|
| EJOT 8715100540 | 100.0 |
| EJOT 8715120540 | 120.0 |
| EJOT 8715140540 | 140.0 |
| EJOT 8715160540 | 160.0 |
| EJOT 8715180540 | 180.0 |
| EJOT 8715200540 | 200.0 |
| EJOT 8715220540 | 220.0 |
| EJOT 8715240540 | 240.0 |
| EJOT 8715260540 | 260.0 |
| EJOT 8715280540 | 280.0 |
| EJOT 8715300540 | 300.0 |
| EJOT 8715320540 | 320.0 |
| EJOT 8715340540 | 340.0 |
| EJOT 8715360540 | 360.0 |
| EJOT 8715380540 | 380.0 |
| EJOT 8715400540 | 400.0 |
| EJOT 8715420540 | 420.0 |
| EJOT 8715440540 | 440.0 |
| EJOT 8715460540 | 460.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ejotherm® SDK UEJOT · 4 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics ejotherm® SDK U
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Documented series dimensions: nominal Ø 8 mm; length 45–105 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Masonry, Perforated masonry, Aerated concrete. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Anchor Ø (mm) | Length (mm) | Activation method | Anchorage depth=25 |
|---|---|---|---|---|
| EJOT 8798045400 | 8.0 | 45.0 | Fissaggio ad avvitamento | 20.0 |
| EJOT 8798065400 | 8.0 | 65.0 | Fissaggio ad avvitamento | 40.0 |
| EJOT 8798085400 | 8.0 | 85.0 | Fissaggio ad avvitamento | 60.0 |
| EJOT 8798105400 | 8.0 | 105.0 | Fissaggio ad avvitamento | 80.0 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
ejotherm® NK UEJOT · 3 referencesFixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.Full description and technical table ↓

Series characteristics ejotherm® NK U
Fixing or component connecting insulation board to the substrate. Length, plate and anchoring element must be assessed in the ETICS system configuration.
Documented series dimensions: nominal Ø 8 mm; length 45–85 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Concrete, Perforated masonry, Aerated concrete. Check the application scope for the individual part.
Identify insulation type and thickness, non-load-bearing layers and substrate category. Anchor number and layout require ETICS-system and wind-action verification; plate diameter alone is insufficient.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Anchor Ø (mm) | Length (mm) | Activation method |
|---|---|---|---|
| EJOT 8797045400 | 8.0 | 45.0 | Fissaggio a percussione |
| EJOT 8797065400 | 8.0 | 65.0 | Fissaggio a percussione |
| EJOT 8797085400 | 8.0 | 85.0 | Fissaggio a percussione |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
Anchor finder
Search by part number or select declared characteristics. Missing data do not satisfy a dimensional filter.
Request technical review or a quotation
Select a finder reference or describe the application.
FAQ
How do I select an anchor?
Start with substrate, load and environment, then identify configuration, depth, distances and part-specific documentation. The finder selects catalogue references and does not perform a design check.
Does equal diameter mean equal capacity?
No. Geometry, material, anchorage and technical assessment may differ. Dimensional comparison does not establish technical equivalence or interchangeability.
Do all anchors have an ETA and CE marking?
These cannot be assigned to an entire category. Check the product documentation, scope and applicability to the specific size. An ETA link does not extend its assessment to other parts.
What information is needed for an enquiry?
Part number or family, quantity, substrate material and condition, thicknesses, fixing geometry, environment, actions and required documents. For resins, also specify temperature and hole conditions.
Sources and documentation
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Dueemme Sidol S.r.l. · Sesto San Giovanni, Milan · Supply for industrial customers and OEMs.