Sleeves and components for bonded anchors
Mesh sleeves and metal components must be matched to the specified bonded-anchor system. In perforated substrates, a sleeve may contain the resin and control anchorage formation.

Features and selection criteria
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Designs, materials and substrates
This family contains 9 series or reference groups, with 69 catalogue rows. Series photographs help distinguish geometries and fixing methods; they do not necessarily represent every size in the range.
Documented materials
Steel · Stainless A4 · Other polymers · Resin
Substrates mentioned in the sources
Masonry · Perforated masonry
This list describes the family and does not assign every substrate to every variant.
Information to define before selection
| Parameter | What to check |
|---|---|
| Load-bearing substrate | Material type, strength, any cracking, useful thickness and hole conditions. Compatibility must be established for the selected design and size. |
| Fixing geometry | Total length, body or thread diameter and drill diameter are distinct parameters. Through-fixings must allow for fixture thickness and non-load-bearing layers. |
| Depth and distances | Compare hole depth, nominal or effective anchorage depth, edge distances and spacing. A deeper hole does not automatically increase fixing capacity. |
| Environment and exposure | Check material and coating of all components, temperature and service conditions. A2, A4 and HCR stainless designs require selection appropriate to the environment. |
| Loads and documentation | Define action directions and combinations and check the part-specific document. Dimensional data identify the part but do not replace a design verification. |
Installation sequence to verify
- Identify the resin system to which the combination belongs.
- Compare sleeve, hole and rod diameter and length.
- In perforated substrates install the sleeve in the prescribed position.
- Follow the resin quantity, sequence and timing for the complete system.
This sequence guides the reading of the instructions. Diameters, depths, equipment and tightening values remain those of the specific variant.
Series and technical tables
DAF02Tecfi · 9 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.Full description and technical table ↓

Series characteristics DAF02
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.
Materials represented by the variants: Steel.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Misura M | Length L (mm) | Inserimento hef | Codolo esagonale |
|---|---|---|---|---|
| Tecfi DAF 02 08 110 | M8 | 110 | 80 | 5 |
| Tecfi DAF 02 10 130 | M10 | 130 | 90 | 7 |
| Tecfi DAF 02 12 160 | M12 | 160 | 110 | 8 |
| Tecfi DAF 02 12 220 | M12 | 220 | 165 | 8 |
| Tecfi DAF 02 16 190 | M16 | 190 | 125 | 12 |
| Tecfi DAF 02 16 260 | M16 | 260 | 190 | 12 |
| Tecfi DAF 02 20 260 | M20 | 260 | 170 | 12 |
| Tecfi DAF 02 24 300 | M24 | 300 | 210 | 13 |
| Tecfi DAF 02 30 380 | M30 | 380 | 280 | 13 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
DAF72Tecfi · 7 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.Full description and technical table ↓

Series characteristics DAF72
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.
Materials represented by the variants: Stainless A4.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Misura M | Length L (mm) | Inserimento hef | Codolo esagonale |
|---|---|---|---|---|
| Tecfi DAF 72 08 110 | M8 | 110 | 80 | 5 |
| Tecfi DAF 72 10 130 | M10 | 130 | 90 | 7 |
| Tecfi DAF 72 12 160 | M12 | 160 | 110 | 8 |
| Tecfi DAF 72 16 190 | M16 | 190 | 125 | 12 |
| Tecfi DAF 72 20 260 | M20 | 260 | 170 | 12 |
| Tecfi DAF 72 24 300 | M24 | 300 | 210 | 13 |
| Tecfi DAF 72 30 380 | M30 | 380 | 280 | 13 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
DAT02Tecfi · 24 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.Full description and technical table ↓

Series characteristics DAT02
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Misura M | Length L (mm) |
|---|---|---|
| Tecfi DAT 02 06 060 | M6 | 60 |
| Tecfi DAT 02 06 090 | M6 | 90 |
| Tecfi DAT 02 06 100 | M6 | 100 |
| Tecfi DAT 02 06 120 | M6 | 120 |
| Tecfi DAT 02 06 140 | M6 | 140 |
| Tecfi DAT 02 08 075 | M8 | 75 |
| Tecfi DAT 02 08 100 | M8 | 100 |
| Tecfi DAT 02 08 120 | M8 | 120 |
| Tecfi DAT 02 08 140 | M8 | 140 |
| Tecfi DAT 02 08 160 | M8 | 160 |
| Tecfi DAT 02 10 095 | M10 | 95 |
| Tecfi DAT 02 10 125 | M10 | 125 |
| Tecfi DAT 02 10 145 | M10 | 145 |
| Tecfi DAT 02 10 165 | M10 | 165 |
| Tecfi DAT 02 10 185 | M10 | 185 |
| Tecfi DAT 02 12 120 | M12 | 120 |
| Tecfi DAT 02 12 150 | M12 | 150 |
| Tecfi DAT 02 12 180 | M12 | 180 |
| Tecfi DAT 02 12 200 | M12 | 200 |
| Tecfi DAT 02 12 230 | M12 | 230 |
| Tecfi DAT 02 16 175 | M16 | 175 |
| Tecfi DAT 02 16 205 | M16 | 205 |
| Tecfi DAT 02 16 235 | M16 | 235 |
| Tecfi DAT 02 16 255 | M16 | 255 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
LN01Tecfi · 6 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.Full description and technical table ↓

Series characteristics LN01
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.
Materials represented by the variants: Steel.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Misura M | Length L (mm) |
|---|---|---|
| Tecfi LN 01 08 110 | M8 | 110 |
| Tecfi LN 01 10 130 | M10 | 130 |
| Tecfi LN 01 12 160 | M12 | 160 |
| Tecfi LN 01 16 190 | M16 | 190 |
| Tecfi LN 01 20 260 | M20 | 260 |
| Tecfi LN 01 24 300 | M24 | 300 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
FV01Tecfi · 7 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: mesh sleeve.Full description and technical table ↓

Series characteristics FV01
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: mesh sleeve.
Materials represented by the variants: Other polymers.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Diameter Ø (mm) | Length L (mm) | Drill Ø d₀ (mm) | Profondità foro h1 (mm) | Idoneo per accessori M | Part-specific documentation indicators |
|---|---|---|---|---|---|---|
| Tecfi FV 01 12 045 | 12 | 45 | 12 | 50 | 6 ÷ 8 | — |
| Tecfi FV 01 12 060 | 12 | 60 | 12 | 65 | 6 ÷ 8 | — |
| Tecfi FV 01 12 080 | 12 | 80 | 12 | 90 | 6 ÷ 8 | ETA-CE |
| Tecfi FV 01 15 085 | 15 | 85 | 15 | 95 | 8 ÷ 10 | ETA-CE |
| Tecfi FV 01 15 130 | 15 | 130 | 15 | 140 | 8 ÷ 10 | — |
| Tecfi FV 01 15 135 | 15 | 135 | 15 | 145 | 8 ÷ 10 | ETA-CE |
| Tecfi FV 01 20 085 | 20 | 85 | 20 | 95 | 10 ÷ 12 | ETA-CE |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
PM01Tecfi · 4 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: mesh sleeve.Full description and technical table ↓

Series characteristics PM01
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: mesh sleeve.
Materials represented by the variants: Steel.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Diameter Ø (mm) | Length L (mm) | Drill Ø d₀ (mm) | Idoneo per accessori M |
|---|---|---|---|---|
| Tecfi PM 01 12 100 | 10 | 1000 | 12 | 6 ÷ 8 |
| Tecfi PM 01 16 100 | 14 | 1000 | 16 | 8 ÷ 10 |
| Tecfi PM 01 22 100 | 20 | 1000 | 22 | 12 ÷ 16 |
| Tecfi PM 01 30 100 | 28 | 1000 | 30 | 16 ÷ 22 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
FZ01Tecfi · 4 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.Full description and technical table ↓

Series characteristics FZ01
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element.
Materials represented by the variants: Steel.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Diameter Ø (mm) | Length L (mm) | Filetto interno M |
|---|---|---|---|
| Tecfi FZ 01 06 048 | 8 | 48 | M6 |
| Tecfi FZ 01 08 083 | 12 | 80 | M8 |
| Tecfi FZ 01 10 083 | 14 | 80 | M10 |
| Tecfi FZ 01 12 083 | 16 | 80 | M12 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
Bussola retinata USFEJOT · 5 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: mesh sleeve.Full description and technical table ↓

Series characteristics Bussola retinata USF
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: mesh sleeve.
Documented series dimensions: length 80–130 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Substrates mentioned in the series sources: Masonry, Perforated masonry. Check the application scope for the individual part.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Length (mm) | Drill bit Ø (mm) | Hole depth ≤ (mm), source wording | Compatible thread |
|---|---|---|---|---|
| EJOT 9571012080 | 80.0 | 12.0 | 85.0 | M8 |
| EJOT 9571016085 | 85.0 | 16.0 | 85.0 | M8, M10 |
| EJOT 9571016130 | 130.0 | 16.0 | 135.0 | M8, M10 |
| EJOT 9571020085 | 85.0 | 20.0 | 90.0 | M12-M16 |
| EJOT 9571020130 | 130.0 | 20.0 | 135.0 | M12-M16 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
Calzetta SHEJOT · 3 referencesComponent for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: vinylester formulation, epoxy formulation.Full description and technical table ↓

Series characteristics Calzetta SH
Component for the specified bonded-anchor combination. Geometry, dimensions and material must be compatible with resin, substrate and threaded element. Series design: vinylester formulation, epoxy formulation.
Materials represented by the variants: Resin.
Substrates mentioned in the series sources: Perforated masonry. Check the application scope for the individual part.
Check diameters, lengths, rod and resin quantity in the system instructions. Do not substitute components solely because their threads match; generic rods already covered elsewhere in the catalogue are not duplicated here.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Drill bit Ø (mm) | Hole depth ≤ (mm), source wording | Compatible thread |
|---|---|---|---|
| EJOT 9570012080 | 12.0 | 85.0 | M8 |
| EJOT 9570015130 | 16.0 | 135.0 | M8-M12 |
| EJOT 9570020085 | 20.0 | 90.0 | M12 |
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
Anchor finder
Search by part number or select declared characteristics. Missing data do not satisfy a dimensional filter.
Request technical review or a quotation
Select a finder reference or describe the application.
FAQ
How do I select an anchor?
Start with substrate, load and environment, then identify configuration, depth, distances and part-specific documentation. The finder selects catalogue references and does not perform a design check.
Does equal diameter mean equal capacity?
No. Geometry, material, anchorage and technical assessment may differ. Dimensional comparison does not establish technical equivalence or interchangeability.
Do all anchors have an ETA and CE marking?
These cannot be assigned to an entire category. Check the product documentation, scope and applicability to the specific size. An ETA link does not extend its assessment to other parts.
What information is needed for an enquiry?
Part number or family, quantity, substrate material and condition, thicknesses, fixing geometry, environment, actions and required documents. For resins, also specify temperature and hole conditions.
Sources and documentation
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Dueemme Sidol S.r.l. · Sesto San Giovanni, Milan · Supply for industrial customers and OEMs.