Aerated concrete fixings
Aerated concrete requires geometries suited to its porous structure. Expansion, screwing or cutting into the substrate are design-specific functions.

Features and selection criteria
Specify block class and density, available depth and edge conditions. Ordinary concrete tables cannot automatically be applied to aerated concrete.
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Designs, materials and substrates
This family contains 2 series or reference groups, with 10 catalogue rows. Series photographs help distinguish geometries and fixing methods; they do not necessarily represent every size in the range.
Documented materials
Steel
Substrates mentioned in the sources
Check the reference documentation.
This list describes the family and does not assign every substrate to every variant.
Information to define before selection
| Parameter | What to check |
|---|---|
| Load-bearing substrate | Material type, strength, any cracking, useful thickness and hole conditions. Compatibility must be established for the selected design and size. |
| Fixing geometry | Total length, body or thread diameter and drill diameter are distinct parameters. Through-fixings must allow for fixture thickness and non-load-bearing layers. |
| Depth and distances | Compare hole depth, nominal or effective anchorage depth, edge distances and spacing. A deeper hole does not automatically increase fixing capacity. |
| Environment and exposure | Check material and coating of all components, temperature and service conditions. A2, A4 and HCR stainless designs require selection appropriate to the environment. |
| Loads and documentation | Define action directions and combinations and check the part-specific document. Dimensional data identify the part but do not replace a design verification. |
Installation sequence to verify
- Identify aerated concrete class and density.
- Use the drilling or screwing method specified for the design.
- Maintain anchorage depth and edge distances.
- Match the screw and check substrate integrity around the fixing.
This sequence guides the reading of the instructions. Diameters, depths, equipment and tightening values remain those of the specific variant.
Series and technical tables
TZ01Tecfi · 5 referencesGeometry designed for anchoring in aerated concrete. Select the fixing in relation to block density and characteristics.Full description and technical table ↓

Series characteristics TZ01
Geometry designed for anchoring in aerated concrete. Select the fixing in relation to block density and characteristics.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 5–10 mm; drill Ø 6–12 mm; length 30–60 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Specify block class and density, available depth and edge conditions. Ordinary concrete tables cannot automatically be applied to aerated concrete.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Drill Ø d₀ (mm) | Anchor length (mm) | Anchor body Ø (mm) | Material | Finish |
|---|---|---|---|---|---|
| Tecfi TZ 01 05 030 | 6 | 30 | 5 | Steel | Zinc plated |
| Tecfi TZ 01 06 032 | 8 | 32 | 6 | Steel | Zinc plated |
| Tecfi TZ 01 08 038 | 10 | 38 | 8 | Steel | Zinc plated |
| Tecfi TZ 01 08 060 | 10 | 60 | 8 | Steel | Zinc plated |
| Tecfi TZ 01 10 060 | 12 | 60 | 10 | Steel | Zinc plated |
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
TZ02Tecfi · 5 referencesGeometry designed for anchoring in aerated concrete. Select the fixing in relation to block density and characteristics.Full description and technical table ↓

Series characteristics TZ02
Geometry designed for anchoring in aerated concrete. Select the fixing in relation to block density and characteristics.
Materials represented by the variants: Steel.
Documented series dimensions: nominal Ø 5–10 mm; drill Ø 6–12 mm; length 30–60 mm. Endpoints describe the listed sizes rather than a continuous range. Use the part-specific row for each combination.
Specify block class and density, available depth and edge conditions. Ordinary concrete tables cannot automatically be applied to aerated concrete.
The table lists available characteristics for each reference; alternative installation configurations remain separate. Refer to the linked documents for torque, loads and conditions not specified in the table.
View the manufacturer’s product page ↗Part-specific technical table
Values and symbols follow the source. “—” = not stated in the table, not zero. The std, red1 and red2 designations identify different manufacturer configurations.
| Part number and source | Drill Ø d₀ (mm) | Anchor length (mm) | Anchor body Ø (mm) | Material | Finish | Drive | Diameter vite Øs | Length vite Ls |
|---|---|---|---|---|---|---|---|---|
| Tecfi TZ 02 05 030 | 6 | 30 | 5 | Steel | Zinc plated | Impronta a Croce tipo Z | 4.5 | 45 |
| Tecfi TZ 02 06 032 | 8 | 32 | 6 | Steel | Zinc plated | Impronta a Croce tipo Z | 5 | 45 |
| Tecfi TZ 02 08 038 | 10 | 38 | 8 | Steel | Zinc plated | Impronta a Croce tipo Z | 6 | 60 |
| Tecfi TZ 02 08 060 | 10 | 60 | 8 | Steel | Zinc plated | Impronta a Croce tipo Z | 6 | 80 |
| Tecfi TZ 02 10 060 | 12 | 60 | 10 | Steel | Zinc plated | Impronta a Croce tipo Z | 6 | 80 |
System documents
ETA, fire or seismic indicators listed for one part do not extend to other sizes. Permissible loads and torque values not listed here must be obtained from the applicable document and actual configuration.
Anchor finder
Search by part number or select declared characteristics. Missing data do not satisfy a dimensional filter.
Request technical review or a quotation
Select a finder reference or describe the application.
FAQ
How do I select an anchor?
Start with substrate, load and environment, then identify configuration, depth, distances and part-specific documentation. The finder selects catalogue references and does not perform a design check.
Does equal diameter mean equal capacity?
No. Geometry, material, anchorage and technical assessment may differ. Dimensional comparison does not establish technical equivalence or interchangeability.
Do all anchors have an ETA and CE marking?
These cannot be assigned to an entire category. Check the product documentation, scope and applicability to the specific size. An ETA link does not extend its assessment to other parts.
What information is needed for an enquiry?
Part number or family, quantity, substrate material and condition, thicknesses, fixing geometry, environment, actions and required documents. For resins, also specify temperature and hole conditions.
Sources and documentation
Dimensions transcribed from the listed sources, checked on 13 November 2026. “—” means not stated or not normalised, not zero. Nominal diameter, thread and drill diameter are distinct. Consult the specific variant documentation for loads, installation and permitted applications. Availability is confirmed at quotation.
Dueemme Sidol S.r.l. · Sesto San Giovanni, Milan · Supply for industrial customers and OEMs.